The probing depth of total electron yield in the sub-keV range: TEY-XAS and X-PEEM
نویسندگان
چکیده
X-ray absorption spectra can be collected in multiple ways, each exhibiting a different probing depth. The total electron yield signal contains contributions from primary, Auger and secondary electrons. We present data on the total electron yield probing depth at core level energies ranging from 77 to 929 eV. By coating materials with chromium overlayers, we find that the maximum probing depth increases with core level energy from 15 to 141 A. We demonstrate that the Auger electron contribution to total electron yield intensity is negligible, therefore X-ray absorption spectra acquired in X-ray PhotoElectron Emission spectroMicroscopy (X-PEEM) are equivalent to spectra acquired by total electron yield. We find that the signal intensity decreases exponentially with coating thickness, and that total electron yield probing depth and Auger electron range (calculated in the continuously slowing down approximation) are similar at low energies, but diverge for kinetic energies above 400 eV. 2003 Elsevier Science B.V. All rights reserved.
منابع مشابه
Revisiting the total ion yield x-ray absorption spectra of liquid water microjets.
Measurements of the total ion yield (TIY) x-ray absorption spectrum (XAS) of liquid water by Wilson et al (2002 J. Phys.: Condens. Matter 14 L221 and 2001 J. Phys. Chem. B 105 3346) have been revisited in light of new experimental and theoretical efforts by our group. Previously, the TIY spectrum was interpreted as a distinct measure of the electronic structure of the liquid water surface. Howe...
متن کاملQuantitative Analysis by X-ray Induced Total Electron Yield (tey) Compared to Xrfa
The theoretical concepts of the two methods are similar. Consequently, comparable fundamental parameter algorithms can be developed and applied to quantitative analysis of bulk specimens and to investigation of thin layers by TEY and by XRFA. Whereas the sampling depth of XRFA is determined by photoelectric absorption, for TEY the escape probability of electrons reduces this quantity to values ...
متن کاملShielding simulations for safe use of curtain electron accelerator by MCNP4C
In an electron curtain accelerator, when the electron beam passes through the titanium exit window of the accelerator chamber, X-ray photons are produced as a negative by-product of retarding accelerated electrons. Controlling the produced X-ray photons to avoid their detrimental effects or in fact, proper shielding of the accelerator is an important issue that has to be considered in the use o...
متن کاملEffect of reflection and refraction on NEXAFS spectra measured in TEY mode
The evolution of near-edge X-ray absorption fine structure in the vicinity of the K-absorption edge of oxygen for HfO2 over a wide range of incidence angles is analyzed by simultaneous implementation of the total-electron-yield (TEY) method and X-ray reflection spectroscopy. It is established that the effect of refraction on the TEY spectrum is greater than that of reflection and extends into t...
متن کاملQUANTITATIVE SURFACE ANALYSIS BY X-RAY INDUCED ELECTRON EMISSION, H. Ebel, R. Svagera and M.F. Ebel, pp. 519-533
The theoretical approach of TEY (total electron yield) for quantitative surface analysis is demonstrated for binary Au-Cu alloys and the evaluation of thin layer measurements on the example of thin aGa,,As layers on GaAs substrates. Further considerations deal with detection limits of the method. An interesting feature of TEY is the possibility to quantify buried thin layers. The detection limi...
متن کامل