In this paper, a methodology for designing an optimal monitoring architecture by using a limited number of PMU (Phasor Measurement Units) and a PDC (Phase Data Concentrator) is proposed. The optimal design problem consists in defining the optimal location of both the PMU and the PDC by maximizing the expected value of the trace of the observability gramian of the power system over a large number of set point scenarii, while minimizing the communication infrastructure cost. Furthermore, a nonlinear dynamical EKF (Extended Kalman Filtering) state-observer is proposed. This state-observer allows to take transient phenomena into account for wide-area power systems described by algebraicdifferential equations, without needing nonlinear inversion techniques. Application to a 5-bus power system is also presented and demontrates the effectiveness of the approach.
منابع مشابه
PMU Placement Methods in Power Systems based on Evolutionary Algorithms and GPS Receiver
In this paper, optimal placement of Phasor Measurement Unit (PMU) using Global Positioning System (GPS) is discussed. Ant Colony Optimization (ACO), Simulated Annealing (SA), Particle Swarm Optimization (PSO) and Genetic Algorithm (GA) are used for this problem. Pheromone evaporation coefficient and the probability of moving from state x to state y by ant are introduced into the ACO. The modifi...
متن کاملPresenting a New Method Based on Branch Placement for Optimal Placement of Phasor Measurement Units
In this paper, a new method based on branch placement for the optimal positioning of Phasor Measurement Units (PMUs) in power systems is proposed. In this method, the PMUs are in type of single-channel and are installed at the beginning of the branches. Therefore, they are able to measure the bus voltages. Also, the installation of the PMUs on the branches increases the security of observabilit...
متن کاملOptimal PMU Placement Considering with HVDC Links and Their Voltage Stability Requirements
In wide area measurement systems, PMUs are the main component measuring real time synchronized data from different buses. Installation of PMUs at all buses is a primary way to provide full observability of the power network. However, it is not practical in real networks due to the relatively expensive cost of PMUs and other technical limitations. Optimal PMU Placement (OPP) is an optimization p...
متن کاملObservability-Enhanced PMU Placement Considering Conventional Measurements and Contingencies
Phasor Measurement Units (PMUs) are in growing attention in recent power systems because of their paramount abilities in state estimation. PMUs are placed in existing power systems where there are already installed conventional measurements, which can be helpful if they are considered in PMU optimal placement. In this paper, a method is proposed for optimal placement of PMUs incorporating conve...
متن کاملOptimal Multistage Scheduling of Pmu Placement for Power System Observability
The standards of power system monitoring, control and protection are elevated by Phasor Measurement Units (PMUs) as an auspicious tool. It is the purpose of this paper to determine the optimal number and locations of PMUs so as to make the system measurement model observable and also estimate the power system state. The proposed modelling approach which models PMU placement as an integer linear...
متن کامل