Comparison of Thermal Comfort by Radiant Heating and Convective Heating

نویسندگان

  • Shigeru Imai
  • Shoichi Kojima
چکیده

Currently, convective heating with a heat-pump system, which has high energy efficiency, is popular for room heating. However, it is possible that energy savings using convective heating can be further improved using heat pumps that service both occupied and unoccupied spaces. Moreover, convective heating increases vertical temperature gradients in a room; thus, it is hard to say whether occupants are being provided with sufficient thermal comfort. The purpose of this study is to compare the thermal comfort provided by both radiant and convective heating systems. In this study, a small office room was modeled, and then temperature and airflow distributions in the room were calculated by Computational Fluid Dynamics (CFD) simulations using ESP-r (Environmental research simulation software). Furthermore, distributions of Standard Effective Temperatures (SET * ) were calculated using the air temperature distributions obtained from the CFD simulations, which allows us to compare the thermal comfort provided by convective heating with that provided by radiant heating. The results show that radiant heating can provide satisfactory thermal comfort, even when the room air temperature is low. However, thermal comfort also depends on the temperature of blowing air, and blowing air must reach occupied regions; thus, only radiant heating cannot circulate sufficient air. In contrast, convective heating increases vertical temperature gradients in a room. Therefore, rather than using only radiant or convective heating, it may be more effective to combine them efficiently.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

بررسی عملکرد حرارتی سامانه‌های گرمایش تابشی سقفی و تاثیر آن بر سطح آسایش حرارتی کارگران در کارگاه‌های معمول صنعتی

Introduction: Introduction: Thermal comforts are one of the most human concerns in working as was as living environments in the past half century. Thermal comfort is the condition in which people are satisfied with the thermal environment, mentally. One of the new heating system employed in individual units is radiant heating system .The purpose of this study was to investigate the performance ...

متن کامل

Impact of the Position of the Radiators on Energy Consumption and Thermal Comfort in a Mixed Radiant and Convective Heating System

This paper studies the heating load and thermal comfort distribution in a typical office with a mixed radiant and convective heating system for two different locations of radiant heat sources. Accurately estimating the heating load in a mixed heating space requires careful consideration of the energy balance on each room surface and the comfort level in the space. A pure radiant heating system ...

متن کامل

A Coupled Airflow-and-Energy Simulation Program for Indoor Thermal Environment Studies (RP-927)

Design of a thermally comfortable indoor environment requires detailed information about distribution of air velocity, air temperature, relative humidity, and mean radiant temperature and about heating/cooling load in a space. This research has developed a coupled airflow-and-energy simulation program to calculate simultaneously the distributions of indoor airflow and thermal comfort and heatin...

متن کامل

Performances of Low Temperature Radiant Heating Systems

The low temperature radiant systems are very complex because they involve different mechanisms of heat transfer: heat conduction through the walls, heat convection between the heating panel and the indoor air, heat radiation between the heating panel and the surrounding areas, and the heat conduction between the floor and the ground. The main essence of the low-temperature air systems is to pro...

متن کامل

Radiant heat transfer of bicycle helmets and visors.

Twenty-six bicycle helmets and their associated visors were characterized for radiant heat transfer using a thermal manikin headform in a climate chamber to assess their ability to protect the wearer from heating by the sun. A single configuration for applied radiant flow of 9.3 W was used to assess the roles of the forward and upper vents and the visor. The helmets shielded 50-75% of the radia...