Biomechanical effects of morphological variations of the cortical wall at the bone-cement interface
نویسندگان
چکیده
BACKGROUND The integrity of bone-cement interface is very important for the stabilization and long-term sustain of cemented prosthesis. Variations in the bone-cement interface morphology may affect the mechanical response of the shape-closed interlock. METHODS Self-developed new reamer was used to process fresh pig reamed femoral canal, creating cortical grooves in the canal wall of experimental group. The biomechanical effects of varying the morphology with grooves of the bone-cement interface were investigated using finite element analysis (FEA) and validated using companion experimental data. Micro-CT scans were used to document interlock morphology. RESULTS The contact area of the bone-cement interface was greater (P < 0.05) for the experimental group (5470 ± 265 mm(2)) when compared to the specimens of control group (5289 ± 299 mm(2)). The mechanical responses to tensile loading and anti-torsion showed that the specimens with grooves were stronger (P < 0.05) at the bone-cement interface than the specimens without grooves. There were positively significant correlation between the contact area and the tensile force (r (2) = 0.85) and the maximal torsion (r (2) = 0.77) at the bone-cement interface. The volume of cement of the experimental group (7688 ± 278 mm(3)) was greater (P < 0.05) than of the control group (5764 ± 186 mm(3)). There were positively significant correlations between the volume of cement and the tensile force (r (2) = 0.90) and the maximal torsion (r (2) = 0.97) at the bone-cement interface. The FEA results compared favorably to the tensile and torsion relationships determined experimentally. More cracks occurred in the cement than in the bone. CONCLUSIONS Converting the standard reaming process from a smooth bore cortical tube to the one with grooves permits the cement to interlock with the reamed bony wall. This would increase the strength of the bone-cement interface.
منابع مشابه
The Most Appropriate Reconstruction Method Following Giant Cell Tumor Curettage: A Biomechanical Approach
Giant cell tumor (GCT) is a primary and benign tumor of bone, albeit locally aggressive in some cases, such as in the epi-metaphyseal region of long bones, predominantly the distal end of femur and proximal end of tibia (1). There are a variety of treatments for a bone affected by GCT, ranging from chemotherapy, radiotherapy, embolization, and cryosurgery, to surgery with the use of chemical or...
متن کاملمقایسه اثر مواد مختلف سازنده ساختار فلزی روکش بر توزیع تنش پیرامون ایمپلنت با آنالیز اجزاء محدود سه بعدی
Objectives: Despite the high success rate, implant-supported prostheses fail in some cases. Control of the applied forces is an important factor determining the success or failure of implants. Complete understanding of the biomechanical principles in implant-supported prostheses is necessary for offering an appropriate custom-made treatment plan for each patient and reducing the risk of functio...
متن کاملBiomechanical Evaluation of Temperature Rising and Applied Force in Controlled Cortical Bone Drilling: An Animal in Vitro Study
Background: The present study was conducted to quantify the relationships between bone drilling process parameters(i.e., feed rate, resting time, exit rate, and drill bit diameter) and drilling outcome parameters (i.e., thrust force andmaximum temperature).Methods: This study utilized 10-cm cortical bovine samples to evaluate the effects of four independent parameters,in...
متن کاملAcrylic antibiotic-loaded bone cement: a basic study
Abstract Objective: The aim of this study was to evaluate the efficacy of antibiotic-loaded bone cement in controlling local infection and in regard to its physical characteristics, elastic modulus, and tensile strength in-vitro. Methods: Acrylic bone cement, based on polymethylmethacrylate (PMMA) was mixed with the powder form of three antibiotics, i.e., gentamicin, tobramycin, and...
متن کاملInfluence of bone cements on bone-screw interfaces in the third metacarpal and third metatarsal bones of horses.
OBJECTIVE To compare biomechanical strength, interface quality, and effects of bone healing in bone-implant interfaces that were untreated or treated with calcium phosphate cement (Ca-cement), magnesium phosphate cement (Mg-cement), or polymethylmethacrylate (PMMA) in horses. ANIMALS 6 adult horses. PROCEDURES 4 screw holes were created (day 0) in each third metacarpal and third metatarsal ...
متن کامل