Influence of refractory ceramic fibres - asbestos substitute - on the selected parameters of bronchoalveolar lavage 6 months after intratracheal instillation to W-rats.
نویسندگان
چکیده
Industrial fibrous dusts are applied in many industrial branches and represent adverse factors in occupational and environmental area. Refractory ceramic fibers (RCFs) - amorphous alumina silicates - are used as one kind of asbestos substitutes. Because RCFs are relatively durable and some RCFs are respirable, they may present a potential health hazard by inhalation. The aim of present work was to find out the subchronic effect of RCFs on selected parameters of bronchoalveolar lavage (BAL) in W-rats, confirm the biopersistence of RCFs after 6 month instillation and contribute to the understanding of the pathomechanism of lung injury after fibrous dust exposure. Wistar rats were intratracheally instilled with 4 mg/animal of RCFs - exposed group and with 0.4 ml saline solution/animal - control group. Animals were sacrificed after 6 month exposure. Bronchoalveolar lavage (BAL) was performed and selected BAL parameters (mainly inflammatory and cytotoxic) were examined. After treatment with RCFs the following changes were observed: statistically significant increase in proportion of lymphocytes and polymorphonuclears as well as in % of immature alveolar macrophages (AM) and phagocytic activity of AM; statistically significant decrease in viability of AM and proportion of AM (from the differential cell count) in comparison with the control group. The results of this study indicated that RCFs even 6 months after intratracheal instillation very significantly changed the majority of examined BAL parameters. The presence of inflammatory and cytotoxic response in lung may signalize beginning or developing disease process.
منابع مشابه
Evaluation of Pulmonary Toxicity of Zinc Oxide Nanoparticles Following Inhalation and Intratracheal Instillation
We conducted inhalation and intratracheal instillation studies of zinc oxide (ZnO) nanoparticles in order to examine their pulmonary toxicity. F344 rats were received intratracheal instillation at 0.2 or 1 mg of ZnO nanoparticles with a primary diameter of 35 nm that were well-dispersed in distilled water. Cell analysis and chemokines in bronchoalveolar lavage fluid (BALF) were analyzed at thre...
متن کاملBiopersistence of NiO and TiO2 Nanoparticles Following Intratracheal Instillation and Inhalation
The hazards of various types of nanoparticles with high functionality have not been fully assessed. We investigated the usefulness of biopersistence as a hazard indicator of nanoparticles by performing inhalation and intratracheal instillation studies and comparing the biopersistence of two nanoparticles with different toxicities: NiO and TiO₂ nanoparticles with high and low toxicity among nano...
متن کاملPulmonary toxicity of well-dispersed cerium oxide nanoparticles following intratracheal instillation and inhalation
We performed inhalation and intratracheal instillation studies of cerium dioxide (CeO2) nanoparticles in order to investigate their pulmonary toxicity, and observed pulmonary inflammation not only in the acute and but also in the chronic phases. In the intratracheal instillation study, F344 rats were exposed to 0.2 mg or 1 mg of CeO2 nanoparticles. Cell analysis and chemokines in bronchoalveola...
متن کاملIn vivo and in vitro proinflammatory effects of particulate air pollution (PM10).
Epidemiologic studies have reported associations between fine particulate air pollution, especially particles less than 10 mm in diameter (PM10), and the development of exacerbations of asthma and chronic obstructive pulmonary disease. However, the mechanism is unknown. We tested our hypothesis that PM10 induces oxidant stress, causing inflammation and injury to airway epithelium. We assessed t...
متن کاملIntratracheal instillation versus intratracheal inhalation: influence of cytokines on inflammatory response.
Our laboratory has developed a method of particle exposure whereby anesthetized rats intratracheally inhale, at a regulated breathing rate and pressure, an aerosolized test material. This method is capable of delivering considerable doses in a short time period and, unlike the commonly used method of intratracheal instillation, does so with an even particle distribution throughout the lung. Ear...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Biomedical papers of the Medical Faculty of the University Palacky, Olomouc, Czechoslovakia
دوره 149 2 شماره
صفحات -
تاریخ انتشار 2005