Uncertainties Propagation Study of the Transit Time Methods in Ultrasonic Anemometers

نویسندگان

  • Will Almeida
  • Bruno Costa
  • Raimundo Freire
  • Francisco Santos
  • Sebastian Catunda
چکیده

The fluids speed measurement, particularly the air speed measurement is very important for industrial and laboratory applications. The ultrasonic method is among the most common methods used for determining the air speed. The basic principle to measure a fluid speed, using an ultrasonic transducer, is based on the modification of the apparent propagation speed of an ultrasonic signal caused by the fluid movement. Particularly, the method based on the Transit Time, which can use the techniques of Phase Difference and Time Difference, is one of the most used. In this work we carry on a comparative study of the uncertainty propagation employing these techniques in ultrasonic anemometers for determining the air speed.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Numerical simulation of transit-time ultrasonic flowmeters: uncertainties due to flow profile and fluid turbulence.

Flowmeter measurement using the ultrasonic transit-time method is based on the apparent difference of the sound velocity in the flow direction and in the opposite direction. This method gives a flow velocity averaged along a particular acoustical path. To convert this path velocity to a velocity averaged over the entire cross-section of the flowing medium, the knowledge of the flow velocity pro...

متن کامل

Optimized Blood Volume Monitoring during Hemodialysis Procedure based on Ultrasonic Speed Measurement

Fast reduction of blood water volume due to ultra-filtration via hemodialysis machine and critical threshold of blood water volume can result in clinical complications such as hypotension. When blood water volume reduces during hemodialysis process, the concentration of blood forming elements will increase. One of the methods for the monitoring of the concentration changes is ultrasonic speed m...

متن کامل

Independent assessment of source transit time for the BEBIG SagiNova® high dose rate brachytherapy afterloader

Introduction: The dwell time and transit time components contribute to the overall delivered dose to patients in high dose rate (HDR) brachytherapy treatments. The transit time results from source entry and exit as well as source movements between dwell positions. It depends on various parameters such as the source speed profile, source indexer distance to dwell position, and ...

متن کامل

Calculation of 99mTc-DTPA transit times in normal kidney [Persian]

Introduction: Renal dynamic study is a well-established and popular test in routine practice of nuclear medicine. The test is non-invasive, rapid and unique in evaluation of the kidney function. In despite of its clinical values, the parameters derived from renogram are physiologically meaningless. That is due to the fact that renogram is not the true kidney function. From mathematical po...

متن کامل

Piezoceramic Element Design and Fabrication for Ultrasonic Transducer of Gas Meter

Ultrasonic transducers play a significant role in generating and receiving the acoustic waves in ultrasonic flowmeters. Depending on the required accuracy, the ultrasonic transducers can be installed either in one pair or more in an ultrasonic flowmeter. The main part of an ultrasonic transducer is its piezoceramic element. In this work, four piezoceramic elements with different diameter to thi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2006