Repeatability of transcranial Doppler measurements of arterial blood flow velocities in healthy subjects.

نویسندگان

  • P Demolis
  • S Chalon
  • J F Giudicelli
چکیده

1. Transcranial Doppler measurements of the mean blood flow velocity and the resistance index in the middle cerebral artery are used to assess cerebral haemodynamics. The prerequisite for the use of these parameters in clinical pharmacology studies is an evaluation of their repeatability and spontaneous variation with time. 2. Repeatability of transcranial Doppler measurements of mean blood flow velocity and resistance index was investigated in healthy subjects by calculation of the repeatability coefficient as defined by the British Standards Institution. Intra-observer repeatability (comparison of two successive determinations by one observer, n = 30 subjects), between-observer repeatability (comparison of two successive measurements each performed by a different observer, n = 30) and long-term repeatability (comparison of two determinations performed at the same hour with a 1 week interval by one observer, n = 14) were assessed. In addition, the spontaneous evolution with time of mean blood flow velocity and resistance index was determined over an 8 h period (n = 14). 3. Repeatability coefficients for intra-observer repeatability, between-observer repeatability and long-term repeatability were 4.83, 4.59 and 3.32 cm/s for mean blood flow velocity (normal value = 61.2 +/- 10.2 cm/s) and 2.62, 3.12 and 3.49% for resistance index, respectively (normal value = 53.6 +/- 5.9%), indicating that transcranial Doppler measurements are repeatable enough to be used over periods of time of up to 1 week in clinical pharmacology studies. 4. Finally, a time effect was detected for mean blood flow velocity, indicating that this parameter undergoes diurnal variation.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Intracranial Blood Flow Velocity in Patients with β-Thalassemia Intermedia Using Transcranial Doppler Sonography: A Case-Control Study

Introduction. Patients with β-thalassemia intermedia have a higher incidence of thromboembolic events compared to the general population. Previous studies have shown that patients with sickle cell disease, who are also prone to ischemic events, have higher intracranial arterial blood flow velocities measured by transcranial Doppler sonography (TCD). The aim of this study is to evaluate intracra...

متن کامل

Results of Transcranial Doppler in Children with Sickle Cell Disease: Correlation between the Time-Averaged Mean of Maximum Velocity and Some Hematological Characteristics

Abstract Background: Transcranial Doppler ultrasonography results have not been previously studied in among Iranian sickle cell anemia patients. The present study was performed to evaluate the pattern of intracranial flow velocities among Iranian children with sickle cell anemia and the hematological parameters that can affect the time-averaged mean of maximum velocity in major intracranial...

متن کامل

Cerebral autoregulation in orthostatic hypotension. A transcranial Doppler study.

BACKGROUND AND PURPOSE Transcranial Doppler measurements of blood flow velocity permit an assessment of variations in intracranial hemodynamics in response to acute arterial pressure variations. The purpose of this study was to scan healthy volunteers and patients with autonomic failure for differences in cerebral hemodynamic patterns under an acute hypotensive stimulus. METHODS We used trans...

متن کامل

Presentation of a Non-invasive Method of Estimating Arterial Stiffness by Modeling Blood Flow and Arterial Wall Based on the Determination of Elastic Module of Arterial Wall

Introduction: Arterial stiffness is an important predictor of cardiovascular risk. Several indices have been  introduced to estimate the arterial stiffness based on the changes in the brachial blood pressure. Since the  substitution  of  the  blood  pressure  changes  in  the  central  arteries  such  as  carotid  with  the  blood  pressure  changes in the brachial results in error in the blood...

متن کامل

Study of Cardiac Parameters by Pulsed Wave Doppler Echocardiography in Normal Healthy Markhoz Goat

Objective- The aim of this study was to test the repeatability, the variability, and to establish the reference values of PW measurements in healthy Markhoz goats.Design- Retrospective study.Animals- 20 female Markhoz goats.Procedure- Using a standardized PW Doppler echocardiographic protocol, 20healthy adult unsedated female Markhoz goats were investigated three times at one-...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical science

دوره 84 6  شماره 

صفحات  -

تاریخ انتشار 1993