GFR measurement with iohexol and 51Cr-EDTA. A comparison of the two favoured GFR markers in Europe.

نویسندگان

  • E Brändström
  • A Grzegorczyk
  • L Jacobsson
  • P Friberg
  • A Lindahl
  • M Aurell
چکیده

BACKGROUND The aim of the present study was to compare the most commonly used GFR markers for clearance measurements, 51Cr-EDTA and iohexol, using two different methods for iohexol analysis, HPLC and X-ray fluorescence, referring both to the multiple-sample and single-sample calculations, using 51Cr-EDTA as the reference method. METHODS Forty-nine patients with an estimated GFR >40 ml/min were included. 51Cr-EDTA and iohexol were injected simultaneously and blood samples were taken 150, 195 and 240 min after injection of the respective marker. RESULTS The multiple-point clearances, determined from HPLC and X-ray fluorescence, compared to 51Cr-EDTA correlated highly (r=0.92 and 0.95 respectively). The results from single-point clearance comparison, iohexol measured by HPLC vs 51Cr-EDTA, yielded a correlation of r=0.91, while single-point clearance from iohexol, analysed by X-ray fluorescence, obtained a correlation of 0.93 and an intercept statistically different from origo. CONCLUSIONS Iohexol and 51Cr-EDTA are comparable as GFR markers for multiple-point clearance measurements. The single-sample method for GFR >40 ml/min can be used with a high accuracy. The precision and accuracy of X-ray fluorescence analysis of low concentrations of iohexol were less than those of HPLC. Care should therefore be taken when using X-ray fluorescence that the injected dose of iohexol should result in a plasma concentration level of iodine of at least 0.06 mg/ml at the time of blood sampling.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Regional variation in use of exogenous and endogenous glomerular filtration rate (GFR) markers in Sweden

BACKGROUND Markers of renal function (glomerular filtration rate (GFR)) are frequently used in the Swedish health care. GFR is usually estimated based on plasma creatinine concentration, but plasma cystatin C concentration, creatinine clearance, iohexol clearance, and (51)Cr-EDTA clearance are also used. These markers are all part of the daily patient care, but there is little specific informat...

متن کامل

Reproducibilities and responses to food intake of GFR measured with chromium-51-EDTA and iohexol simultaneously and independently in normal subjects.

BACKGROUND The aim was to evaluate the reproducibility of glomerular filtration rate (GFR) measured with iohexol and its response to food in a direct and independent comparison with Cr-51-ethylenediaminetetraacetic acid (EDTA), and examine the influence of two different whole body scaling parameters, body surface area (BSA) and extracellular fluid volume (ECV). METHODS Fasting and non-fasting...

متن کامل

Assessing glomerular filtration rate (GFR) in critically ill patients with acute kidney injury - true GFR versus urinary creatinine clearance and estimating equations

INTRODUCTION Estimation of kidney function in critically ill patients with acute kidney injury (AKI), is important for appropriate dosing of drugs and adjustment of therapeutic strategies, but challenging due to fluctuations in kidney function, creatinine metabolism and fluid balance. Data on the agreement between estimating and gold standard methods to assess glomerular filtration rate (GFR) i...

متن کامل

Donor renal function

• An accurate assessment of the glomerular filtration rate (GFR) should be undertaken in all potential donors. The benefit of obtaining a directly measured GFR (thought to be more accurate) over an estimated GFR, has not been proven in live donors (refer to CARI guidelines titled ‘Use of estimated glomerular filtration rate to assess level of kidney function’ and ‘Direct measurement of glomerul...

متن کامل

Improved estimation of glomerular filtration rate (GFR) by comparison of eGFRcystatin C and eGFRcreatinine

OBJECTIVE GFR-prediction equations based upon cystatin C and creatinine have better diagnostic performance in estimating GFR than equations based upon only one of the two markers. The present work concerns in what way a comparison between separate estimations of GFR based upon cystatin C (eGFR(cystatin C)) or creatinine (eGFR(creatinine)) can be used to evaluate the diagnostic performance of a ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Nephrology, dialysis, transplantation : official publication of the European Dialysis and Transplant Association - European Renal Association

دوره 13 5  شماره 

صفحات  -

تاریخ انتشار 1998