Toric intraocular lens outcome using the manufacturer's prediction of corneal plane equivalent intraocular lens cylinder power.

نویسندگان

  • Michael Goggin
  • Sacha Moore
  • Adrian Esterman
چکیده

OBJECTIVES To describe the refractive outcome of toric intraocular lens (IOL) implantation by comparing the postoperative refractive astigmatism with the preoperative keratometric astigmatism target. METHOD In a university department of a publicly funded hospital, 38 eyes of 29 patients underwent routine cataract surgery with insertion of a toric implant (SN60TT AcrySof Toric). Surgically induced astigmatism was derived using vector analysis of refractive outcome vs predicted postoperative keratometric astigmatism and compared with the targeted induced astigmatism. RESULTS Postoperative remaining refractive astigmatism of 0.97 diopters (D) was achieved vs a target of 0.61 D. A mean (SD) surgically induced astigmatism value of 1.78 (0.89) D was derived compared with a mean (SD) targeted induced astigmatism value of 1.58 (0.47) D (calculated by the manufacturer's online calculator, which predicts IOL corneal plane equivalent cylinder power and postoperative keratometric cylinder). CONCLUSIONS Toric IOLs are a safe, predictable method of astigmatic correction. However, some remaining astigmatism is commonly present owing to the necessary nonzero astigmatic targets imposed by the steps between IOL cylinder powers, variability of axis, and power effects of surgical incisions as well as by underestimation of the corneal plane cylinder power of the IOLs by the manufacturer.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of Two Toric IOL Calculation Methods

Purpose To compare two calculators for toric intraocular lens (IOL) calculation and to evaluate the prediction of refractive outcome. Methods Sixty-four eyes of forty-five patients underwent cataract surgery followed by implantation of a toric intraocular lens (Zeiss Torbi 709 M) calculated by a standard industry calculator using front keratometry values. Prediction error, median absolute err...

متن کامل

Refractive surprise after toric intraocular lens implantation: graph analysis.

PURPOSE To determine the refractive cylinder effect of rotating a toric intraocular lens (IOL) and identify the sources of refractive astigmatic surprise after toric IOL implantation. SETTING Private practice, Melbourne, Australia. DESIGN Experimental study. METHODS Vergence formulas using a standard reduced eye model were used to bring all lens powers to the corneal plane. Double-angle v...

متن کامل

Results of higher power toric intraocular lens implantation.

PURPOSE To evaluate the efficacy, predictability, and safety of coaxial microincision phacoemulsification and toric intraocular lens (IOL) implantation in eyes with high corneal astigmatism. SETTING Two eye clinics in Germany. DESIGN Case series. METHODS Routine cataract extraction using 2.2 mm coaxial phaco equipment and Acrysof toric IOL (3.00 to 6.00 diopters [D] cylinder) implantation...

متن کامل

Treatment of Stable Keratoconus by Cataract Surgery with Toric IOL Implantation

We present the case of a 73-year-old patient who underwent successful phacoemulsification and toric intraocular lens (IOL) implantation to correct high stable astigmatism due to keratoconus and cataract. Preoperative refraction was –3.25 – 4.0 × 98°. A toric IOL (Acrysof SN60T6) with a spherical power of 16.5 D and a cylinder power of 3.75 D at the IOL plane and 2.57 D at the corneal plane was ...

متن کامل

Prediction of Refractive Outcome of Second Eye with Partial Adjustment of Intraocular Lens Power of the First Eye

Background and Objective: This study aimed at comparing the results of refractive cataract surgery in patients undergoing sequential surgeries in both eyes. Considering the preoperative refraction and final refraction of the first eye, it is possible to correct the refrative result of cataract surgery using the adjustment of the second eye intraocular lens (IOL) power. Materials and Methods: T...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Archives of ophthalmology

دوره 129 8  شماره 

صفحات  -

تاریخ انتشار 2011