Nasal swab samples and real-time polymerase chain reaction assays in community-based, longitudinal studies of respiratory viruses: the importance of sample integrity and quality control

نویسندگان

  • Asma N Alsaleh
  • David M Whiley
  • Seweryn Bialasiewicz
  • Stephen B Lambert
  • Robert S Ware
  • Michael D Nissen
  • Theo P Sloots
  • Keith Grimwood
چکیده

BACKGROUND Carefully conducted, community-based, longitudinal studies are required to gain further understanding of the nature and timing of respiratory viruses causing infections in the population. However, such studies pose unique challenges for field specimen collection, including as we have observed the appearance of mould in some nasal swab specimens. We therefore investigated the impact of sample collection quality and the presence of visible mould in samples upon respiratory virus detection by real-time polymerase chain reaction (PCR) assays. METHODS Anterior nasal swab samples were collected from infants participating in an ongoing community-based, longitudinal, dynamic birth cohort study. The samples were first collected from each infant shortly after birth and weekly thereafter. They were then mailed to the laboratory where they were catalogued, stored at -80°C and later screened by PCR for 17 respiratory viruses. The quality of specimen collection was assessed by screening for human deoxyribonucleic acid (DNA) using endogenous retrovirus 3 (ERV3). The impact of ERV3 load upon respiratory virus detection and the impact of visible mould observed in a subset of swabs reaching the laboratory upon both ERV3 loads and respiratory virus detection was determined. RESULTS In total, 4933 nasal swabs were received in the laboratory. ERV3 load in nasal swabs was associated with respiratory virus detection. Reduced respiratory virus detection (odds ratio 0.35; 95% confidence interval 0.27-0.44) was observed in samples where the ERV3 could not be identified. Mould was associated with increased time of samples reaching the laboratory and reduced ERV3 loads and respiratory virus detection. CONCLUSION Suboptimal sample collection and high levels of visible mould can impact negatively upon sample quality. Quality control measures, including monitoring human DNA loads using ERV3 as a marker for epithelial cell components in samples should be undertaken to optimize the validity of real-time PCR results for respiratory virus investigations in community-based studies.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison among nasopharyngeal swab, nasal wash, and oropharyngeal swab for respiratory virus detection in adults with acute pharyngitis

BACKGROUND Acute pharyngitis is frequently seen in primary care. Acute viral pharyngitis may be easily misdiagnosed as acute bacterial pharyngitis. Laboratory-confirmed diagnosis of respiratory viruses is recommended. The purpose of this study was to compare the sensitivities among oropharyngeal swab (OPS), nasopharyngeal swab (NPS), and nasal wash (NW) in adults with acute pharyngitis. METHO...

متن کامل

Development of Multiplex Reverse Transcription-Polymerase Chain Reaction for Simultaneous Detection of Influenza A, B and Adenoviruses

Background and objective:Millions of people in developing countries lose their lives due to acute respiratory infections, such as Influenza A & B and Adeno viruses. Given the importance of rapid identification of the virus, in this study the researchers attempted to design a method that enables detection of influenza A, B, and adenoviruses, quickly and simultaneously. ...

متن کامل

Availability of oral swab sample for the detection of bovine viral diarrhea virus (BVDV) gene from the cattle persistently infected with BVDV.

Bovine nasal and oral discharges were used as samples for bovine viral diarrhea virus (BVDV) gene detection. Viral genes in serum (S), nasal discharge (N) and oral discharge (O) were quantified with real-time polymerase chain reaction using SYBR Green by the relative quantification method, and findings were compared among samples. Although the quantity of the BVDV gene in S was greater than tho...

متن کامل

Development and Evaluation of Real-Time Reverse Transcription Polymerase Chain Reaction Test for Quantitative and Qualitative Recognition of H5 Subtype of Avian Influenza Viruses

Avian influenza viruses (AIV) affect a wide range of birds and mammals, cause severe economic damage to the poultry industry, and pose a serious threat to humans. Highly pathogenic avian influenza viruses (HPAI) H5N1 were first identified in Southeast Asia in 1996 and spread to four continents over the following years. The viruses have caused high mortality in chickens and various bird species ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 14  شماره 

صفحات  -

تاریخ انتشار 2014