Selecting the best site for pacing leads after cardiac surgery by evaluating the asynchrony of myocardial deformation observed with different pacing sites.

نویسندگان

  • José Luis Moya-Mur
  • Enrique Oliva-De Anquin
  • Tomasa Centella-Hernández
  • Soledad Ruiz-Leira
  • Alicia Megías-Sáez
  • Juan Pablo Tomás-Zarlenga
  • Antonio Hernández-Madrid
  • Eva García-Galloway
  • Concepción Moro
چکیده

INTRODUCTION AND OBJECTIVES After cardiac surgery, temporary pacing leads are routinely implanted in the right ventricle (RV). The objective was to investigate the effect of different ventricular pacing locations on cardiac synchrony (by evaluating myocardial deformation, or strain) and efficiency in patients undergoing cardiac surgery. METHODS Interventricular asynchrony (i.e. the difference in the time of onset of deformation between right and left ventricles; Tε-R/L) and intraventricular asynchrony (i.e. the standard deviation and maximum difference in the time of onset of deformation in six segments of the left ventricle [LV]; Tε-SD and Tε-MD, respectively) were assessed in 19 patients. Doppler echocardiography was used to evaluate these parameters and cardiac output after pacing in the RV and in three different LV segments. RESULTS Pacing in the RV resulted in the greatest increases in asynchrony parameters from baseline: Tε-R/L 59.8 ms (standard deviation [SD] 40.5 ms) vs. 28.23 ms (SD 56.9 ms), P=.002; Tε-SD 53.2 ms (SD 34.4 ms) vs. 36.6 ms (SD 34.9 ms), P=.007; and Tε-MD 135.3 ms (SD 82.9 ms) vs. 90.5 ms (SD 87.4 ms), P=.007. Pacing in the LV resulted in less asynchrony: for anterior LV pacing, Tε-R/L was 17.2 ms (SD 53.8 ms), Tε-SD was 35.8 ms (SD 17.9 ms), and Tε-MD was 91.3 ms (SD 45.2). The change from baseline was not significant. Cardiac output was lower after RV pacing than after anterior LV pacing: 4.36 (SD 1) vs. 4.70 (SD 1); P=.001. CONCLUSIONS Pacing in the LV produced less asynchrony than RV pacing. In addition, anterior LV pacing resulted in a higher cardiac output than RV pacing. These findings suggest that the location normally used for temporary leads after cardiac surgery should be changed.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Tissue Doppler echocardiography and biventricular pacing in heart failure: Patient selection, procedural guidance, follow-up, quantification of success

Asynchronous myocardial contraction in heart failure is associated with poor prognosis. Resynchronization can be achieved by biventricular pacing (BVP), which leads to clinical improvement and reverse remodeling. However, there is a substantial subset of patients with wide QRS complexes in the electrocardiogram that does not improve despite BVP. QRS width does not predict benefit of BVP and onl...

متن کامل

Transmural mechanics at left ventricular epicardial pacing site.

Left ventricular (LV) epicardial pacing acutely reduces wall thickening at the pacing site. Because LV epicardial pacing also reduces transverse shear deformation, which is related to myocardial sheet shear, we hypothesized that impaired end-systolic wall thickening at the pacing site is due to reduction in myocardial sheet shear deformation, resulting in a reduced contribution of sheet shear t...

متن کامل

Cardiac memory and cortical memory.

To the Editor: Dr Rosen and colleagues1 elegantly reviewed similarities between cortical and cardiac memory and presented new perspectives on the evolution of cardiac arrhythmias. We propose that, in addition to ion channels and gap junctions, myocyte size can also change in response to altered activation sequence and behaves like a “memory element.” In developing cortical memory, neurons form ...

متن کامل

Minimal invasive epicardial lead implantation: optimizing cardiac resynchronization with a new mapping device for epicardial lead placement.

To optimize resynchronization in biventricular pacing with epicardial leads, mapping to determine the best pacing site, is a prerequisite. A port access surgical mapping technique was developed that allowed multiple pace site selection and reproducible lead evaluation and implantation. Pressure-volume loops analysis was used for real time guidance in targeting epicardial lead placement. Even th...

متن کامل

Improving cardiac function after cardiac surgery by biventricular pacing in patient selected by three-dimensional echocardiography.

We present the case of a 57-year-old woman with severe aortic regurgitation and ventricular dysfunction (ejection fraction 34%) requiring surgical intervention. In pre-operative period, no left ventricular (LV) asynchrony was detected by QRS duration and current echocardiographic techniques, including tissue Doppler imaging. A new echocardiographic technology, the timing of regional volumetric ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Revista espanola de cardiologia

دوره 63 10  شماره 

صفحات  -

تاریخ انتشار 2010