Inappropriate sensing events revealing electrocautery-induced implantable cardioverter–defibrillator lead failure

نویسندگان

  • İlknur Can
  • Alpay Arıbaş
  • Yüksel Dereli
  • Venkatakrishna Tholakanalli
چکیده

Electromagnetic interference (EMI) associated with current implantable cardioverter–defibrillator (ICD) generators and leads are less prone to long-term failure. Thus, it has been suggested that routine post-ICD replacement interrogation of the device may not be necessary. We present the case of a patient who underwent ICD replacement during which therapies were inadvertently not turned off, which lead to EMI and shock and subsequently lead failure. A 52-year-old-man who had ICD (BiotronikLumax340 VR-T, Berlin, Germany) implanted in 2008 presented with an ICD generator end-of-life and was scheduled for generator replacement. Before the procedure device interrogation showed a right ventricular (RV) pacing threshold of 0.6 V at 0.5 ms pulse width, R-wave sensing was 6.7 mV, RV lead pacing impedance was 715 Ω, and shock impedance was 46 Ω. The patient received a Medtronic D384DRG ICD, Minneapolis, USA. During the surgical closure of the device pocket, electrocautery was used for hemostasis, which resulted in EMI and inappropriate 35 J shock (Fig. 1). Postoperatively, inappropriate senses were monitored, which were concordant with lead failure (Fig. 2). The RV pacing threshold increased to 1.25 V at 0.5 ms, and the R-wave sensing decreased to 3.30 mV. Lead impedance measurements were RV pacing at 619 Ω, RV coil at 48 Ω, and SVC coil at 73 Ω. At the second week, a new pace sense lead was uneventfully implanted from the same site and over sense completely ended after the replacement of the lead. Despite the advances in ICD technology, electrocautery, especially when used close to the device, can still lead to lead failure, which might necessitate intervention. Thus, we still recommend routine postprocedural interrogation of the device.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Arrhythmia/Electrophysiology Longevity of Sprint Fidelis Implantable Cardioverter- Defibrillator Leads and Risk Factors for Failure Implications for Patient Management

Background—Sprint Fidelis (Fidelis) implantable cardioverter-defibrillator leads are prone to fractures that have caused adverse events, primarily inappropriate shocks, and a few reported deaths. More than 100 000 patients have Fidelis leads. No independent multicenter long-term performance information exists for this lead, and single-center studies suggest that certain patients are at increase...

متن کامل

A case of inappropriate implantable cardioverter defibrillator therapy induced by T-wave oversensing due to hyperkalemia.

There have been reports of hyperkalemia-induced T-wave oversensing in patients with implantable cardioverter defibrillators (ICDs). However, a comparison of T-wave amplitudes and morphologies between the surface 12-lead electrocardiogram (ECG) and ICD electrogram has not been reported. We present the case of a 70-year-old man who received inappropriate ICD shocks due to hyperkalemia-induced T-w...

متن کامل

THE EFFECT OF NURSE-PEER-LED SUPPORT INTERVENTION ON QUALITY OF LIFE IN PATIENTS WITH AN IMPLANTABLE CARDIOVERTER-DEFIBRILLATOR: A RANDOMIZED CLINICAL TRIAL

Background & Aims: Nowadays, the quality of life and how coping and treatment of patients with an implantable cardiac defibrillator has led to concern and attempts to reduce or eliminate the problems of these patients in the people who provide health care services. This study aimed to determine the effect of nurse-peer-led support intervention on quality of life in patients with an implantable ...

متن کامل

Outcome after implantation of a cardioverter-defibrillator in patients with Brugada syndrome: a multicenter study-part 2.

BACKGROUND Implantable cardioverter-defibrillator indications in Brugada syndrome remain controversial, especially in asymptomatic patients. Previous outcome data are limited by relatively small numbers of patients or short follow-up durations. We report the outcome of patients with Brugada syndrome implanted with an implantable cardioverter-defibrillator in a large multicenter registry. METH...

متن کامل

Longevity of Sprint Fidelis implantable cardioverter-defibrillator leads and risk factors for failure: implications for patient management.

BACKGROUND Sprint Fidelis (Fidelis) implantable cardioverter-defibrillator leads are prone to fractures that have caused adverse events, primarily inappropriate shocks, and a few reported deaths. More than 100 000 patients have Fidelis leads. No independent multicenter long-term performance information exists for this lead, and single-center studies suggest that certain patients are at increase...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 15  شماره 

صفحات  -

تاریخ انتشار 2015