RealAmp Loop-Mediated Isothermal Amplification as a Point-of-Care Test for Diagnosis of Malaria: Neither Too Close nor Too Far.
نویسندگان
چکیده
TO THE EDITOR—Patel et al [1] investigated the usefulness of the real-time fluorescence loop-mediated isothermal amplification (LAMP) assay, RealAmp, as a point-of-care test in diagnosing malaria. In an accompanying editorial, Hsiang et al [2] highlighted some advantages and limitations of LAMP as a point-ofcare test. Molecular techniques are well known for their high sensitivity and specificity [3]. The same characteristics apply in the diagnosis of submicroscopic malaria by molecular techniques, compared with conventional microscopy or antigen-detection methods [4]. LAMP provides results rapidly and uses relatively inexpensive equipment for amplification, compared with conventional polymerase chain reaction (PCR) [5]. However, for validation of DNA extraction methods, it is essential to amplify housekeeping genes and to include positive and negative controls during each run. Because LAMP amplifies genomic DNA several fold, slight contamination during processing may result in false-positive findings, as highlighted byHsiang et al [2]. Thus, it is essential to analyze the results of RealAmp, along with the quality-control results, with caution. Another important factor that requires consideration is the DNA-extraction method of boil and spin, which has been used by Patel et al for onsite extraction of DNA. Briefly, this method requires boiling and centrifugation steps. Therefore, certain equipment and uninterrupted electricity supply are required if many samples have to be screened. Although the authors mentioned that equipment used for performing RealAmp can be run with the help of a rechargeable battery, in remote areas the supply of electricity may be insufficient for recharging the battery [6]. Moreover, whether a rechargeable battery can be used for long periods to power the equipment required for DNA extraction has not been investigated. For performing good-quality molecular work without contamination, separate workstations, along with sterile autoclaved tips and PCR tubes, are required. Before the use of PCR workstations, UV light exposure is required for decontamination. Thus, a regular electricity supply is essential to run an autoclave and for performing RealAmp, which may be the most limiting factor in remote areas. Innovations are required whereby DNA can be isolated by enzymes or reagents without sophisticated equipment, and LAMP can be performed in the same vial by adding reaction mixtures to it so that chances of contamination are minimized and amplification of DNA is achievable [7]. Further, automated systems can be developed in which all steps, starting with DNA extraction and isothermal amplification and continuing through the analysis of results, can be performed quickly, so that contamination can be avoided and the assay made more user friendly [8]. Thus, we are today neither too far nor too close to using LAMP as a point-ofcare test for the diagnosis of malaria.
منابع مشابه
Real-Time Fluorescence Loop Mediated Isothermal Amplification for the Diagnosis of Malaria
BACKGROUND Molecular diagnostic methods can complement existing tools to improve the diagnosis of malaria. However, they require good laboratory infrastructure thereby restricting their use to reference laboratories and research studies. Therefore, adopting molecular tools for routine use in malaria endemic countries will require simpler molecular platforms. The recently developed loop-mediated...
متن کاملLoop-Mediated Isothermal Amplification (LAMP) for the Rapid Diagnosis of Herpes Simplex Virus Type 1 (HSV-1)
Background and Aims: considering difficulties in usual laboratory methods in detection of viral infections, improved DNA-based diagnostic techniques are more reliable. Loop mediated isothermal amplification method (LAMP) is a nucleic acid amplification method that amplifies DNA using six primers which has been developed to diagnose viruses as a rapid and high efficiency test. In this study, the...
متن کاملReal-Time Loop-Mediated Isothermal Amplification (RealAmp) for the Species-Specific Identification of Plasmodium vivax
Plasmodium vivax infections remain a major source of malaria-related morbidity and mortality. Early and accurate diagnosis is an integral component of effective malaria control programs. Conventional molecular diagnostic methods provide accurate results but are often resource-intensive, expensive, have a long turnaround time and are beyond the capacity of most malaria-endemic countries. Our lab...
متن کاملReal-time fluorescence loop-mediated isothermal amplification assay for direct detection of egg drop syndrome virus
BACKGROUND Egg drop syndrome (EDS), caused by the adenovirus "egg drop syndrome virus" (EDSV) causes severe economic losses through reduced egg production in breeder and layer flocks. The diagnosis of EDSV has been done by molecular tools since its complete genome sequence was identified. In order to enhance the capabilities of the real-time fluorescence loop-mediated isothermal amplification (...
متن کاملLoop-mediated isothermal amplification (RT-LAMP): a new approach for the detection of foot-and-mouth disease virus and its sero-types in Pakistan
Successful disease management requires a rapid and sensitive diagnosis method that can recognize early infection even before the manifestation of its clinical signs. The only available field diagnostic tests for foot-and-mouth disease (FMD) are lateral flow devices, commonly known as chromatographic strips. Low sensitivity and inability to detect FMD virus (FMDV) at the serotype level are limit...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The Journal of infectious diseases
دوره 211 10 شماره
صفحات -
تاریخ انتشار 2015