Susceptibility to localized corrosion of stainless steel and NiTi endodontic instruments in irrigating solutions.

نویسندگان

  • M Darabara
  • L Bourithis
  • S Zinelis
  • G D Papadimitriou
چکیده

AIM To evaluate the pitting and crevice corrosion characteristics of stainless steel (SS) and NiTi endodontic files in R-EDTA and NaOCl irrigating solutions. METHODOLOGY The corrosion behaviour of two H-files produced from different SS alloys (Mani, AISI 303 SS, Dentsply Maillefer, AISI 304 SS) and one file produced from NiTi alloy (Maillefer) was determined in R-EDTA and NaOCl irrigating solutions by the cyclic potentiodynamic polarization method. The cutting flutes of 12 files of each material were embedded in an epoxy resin, polished, exposed to the irrigating solutions and used as an electrode. An Ag/AgCl electrode was used as a reference, a platinum plate was used as a counter electrode and polarization curves were obtained for all files in R-EDTA and NaOCl irrigating solutions in 37 degrees C with a potential scan rate of 5 mV min(-1). Corrosion potential (Ecorr), Corrosion current density (Icorr) and Pitting potential (Epit) were calculated from each curve. The results were statistically analysed with two-way anova and Student-Newman-Keuls (SNK) multiple comparison test with materials and irrigating solutions serving as discriminating variables (a = 0.05). RESULTS Cyclic polarization curves presented negative hysteresis implying that pitting or crevice corrosion are not likely to occur for all the materials examined in both irrigating solutions. In NaOCl all materials showed significantly higher Ecorr (P = 0.011) as well as lower Icorr compared with R-EDTA reagent. Moreover, all materials demonstrated equal Epit in NaOCl, which was to be found significantly lower (P = 0.009) than the value of Epit in R-EDTA. CONCLUSIONS None of the tested materials is susceptible to pitting or crevice corrosion in R-EDTA and NaOCl solutions and from this standpoint are appropriate for the production of endodontic files.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Tips to avoid instrument separation in endodontics.

procedural accidents and obstacles to normally routine therapy, at almost any stage of treatment. One of these procedural problems is intracanal instrument fracture. Fractured root canal instruments may include endodontic files (Figure 1) and Gates Glidden burs. Instruments are made from nickel titanium (NiTi), stainless steel or carbon steel. Fracture often results from incorrect use or overus...

متن کامل

The effect of some fluids on surface oxidation and amount of released iron of stainless steel endodontic files.

Endodontic files come in contact with blood, infected pulp tissue, and irrigating solutions during root canal therapy. Some instruments such as stereomicroscopy and scanning electron microscopy are used to observe corrosion of endodontic files which are complicated and dependent on preparation methods. Having knowledge of the corrosion and ion release of endodontic files can help in drawing fir...

متن کامل

Dental students' perceptions about the endodontic treatments performed using NiTi rotary instruments and hand stainless steel files.

This study evaluated the perceptions of Brazilian undergraduate dental students about the endodontic treatments performed using NiTi rotary instruments and hand stainless steel. Data were collected using a questionnaire administered to undergraduate dental students enrolled in endodontic disciplines. The students were divided into 3 groups: G1, students who had treated straight canals with SS h...

متن کامل

Anatomic Endodontic Technology (AET)--a crown-down root canal preparation technique: basic concepts, operative procedure and instruments.

AIM To illustrate the conceptual basis and the operative procedure of the Anatomic Endodontic Technology (AET) technique and to illustrate the specific instruments used in each phase. SUMMARY The basic characteristics of the AET technique are reported. The instruments and procedure are described in three phases: coronal access, coronal-middle preparation and apical preparation. In the first p...

متن کامل

Detection of Procedural Errors with Stainless Steel and NiTi Instruments by Undergraduate Students Using Conventional Radiograph and Cone Beam Computed Tomography

INTRODUCTION This study investigated procedural errors made during root canal preparation using stainless steel and nickel-titanium (NiTi) instruments by undergraduate students, using two diagnostic imaging methods. MATERIALS AND METHODS Sixty human molars were divided into three groups (n=20; group 1: K-Flexofile, group 2: K3, and group 3: BioRace). The root canals were filled with gutta-per...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • International endodontic journal

دوره 37 10  شماره 

صفحات  -

تاریخ انتشار 2004