Effect of hemodilution on the distribution of renal blood flow.

نویسندگان

  • S Migdal
  • E A Alexander
  • F J Bruns
  • A L Riley
  • N G Levinsky
چکیده

We evaluated the effects of hemodilution, expansion of intravascular volume, and expansion of interstitial volume on the distribution of cortical renal blood flow, utilizing the microsphere technique. Hemodilution without volume expansion (saline exchange) produced an increase in fractional blood flow in zone 1 (outermost zone) of the cortex from 34 plus or minus 1% to 43 plus or minus 2% and a decrease in fractional blood flow in zone 4 (innermost zone) from 16 plus or minus 2% to 13 plus or minus 2%. Hemodilution without volume expansion or a decrease in plasma protein concentration (isoncotic exchange) produced a similar redistribution in blood flow in zone 1 from 34 plus or minus 2% to 41 plus or minus 2% and in zone 4 from 14 plus or minus 2% to 10 plus or minus 1%. Hemodilution with intravascular volume expansion (hyperoncotic albumin infusion) also produced a superficial shift; blood flow in zone 1 increased from 27 plus or minus 1% to 30 plus or minus 1% and that in zone 4 decreased from 19 plus or minus 2% to 15 plus or minus 1%. Previous studies have demonstrated a redistribution to the juxtamedullary area after saline expansion. Our data demonstrate that hemodilution causes flow to redistribute to the superficial rather than the deep cortex. This superficial shift appears to be secondary to decrease hematocrit rather than to dilution of plasma proteins or expansions of intravascular volume. The deep shift in cortical blood flow which occurs during saline loading is presumably a consequence of expansion of interstitial volume.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Redistribution of red blood cell flow in microcirculatory networks by hemodilution.

The effect of isovolemic hemodilution on red blood cell flow distribution was studied in complete self-contained microvessel networks of the rat mesentery. Hematocrit, diameter, and length of all vessel segments as well as the topological structure were determined in control networks (systemic hematocrit, 0.54) and after hemodilution (systemic hematocrit, 0.30). Hemodilution was performed by ex...

متن کامل

Evaluation of Retrograde Autologous Priming (RAP) effect on Hemodilution and transfusion rate in operation room and ICU

Abstract Background and Objectives To perform open heart surgery, the patient needs to be placed on the bypass system. This initial volume causes excessive dilution of the patient's blood and the use of blood products, which can alter the surgical procedure and recovery of the patient. The purpose of this study was to evaluate the usefulness of performing a retrograde autologous prime to reduc...

متن کامل

Study of Pulsatile Non-Newtonian Blood Flow Through Abdominal Aorta and Renal Arteries Incorporating Fluid- Structure Interaction

Background: The interaction between the blood and the vessel wall is of great clinical interest in studying cardiovascular diseases, the major causes of death in developed countries.Objective: To understand the effects of incorporating fluid-structure interaction into the simulation of blood flow through an anatomically realistic model of abdominal aorta and renal arteries reconstructed from CT...

متن کامل

Numerical Investigation of Angulation Effects in Stenosed Renal Arteries

Background: Numerical study of angulation effects of renal arteries on blood flow has been of great interest for many researchers.Objective: This paper aims at numerically determining the angulation effects of stenosed renal arteries on blood flow velocity and renal mass flow.Method: An anatomically realistic model of abdominal aorta and renal arteries is reconstructed from CT-scan images and u...

متن کامل

Microcirculatory Networks by Hemodilution

The effect of isovolemic hemodilution on red blood cell flow distribution was studied in complete self-contained microvessel networks of the rat mesentery. Hematocrit, diameter, and length of all vessel segments as well as the topological structure were determined in control networks (systemic hematocrit, 0.54) and after hemodilution (systemic hematocrit, 0.30). Hemodilution was performed by ex...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Circulation research

دوره 36 1  شماره 

صفحات  -

تاریخ انتشار 1975