Readout Electronics of the Na62 Gigatracker System

نویسنده

  • G. DELLACASA
چکیده

A crucial detector of the NA62 experiment is the beam spectrometer named Gigatracker. It consists of three stations of hybrid silicon pixels sensors with 150 ps (rms) of time resolution and 100 μm (rms) of space resolution. In addition the system operates under a high radiation environment and a high density of particles (up to 1.5 MHz/mm in the centre and 0.8 1 GHz in total). To meet these requirements the readout electronics must compensate the discriminators time-walk and the dead time should be below 1%. In order to evaluate the best solution, two readout chips have been developed. One is based on the constant-fraction discriminator technique and the other one is based on the use of a time-over-threshold circuit. The global architectures of both the front-end ASIC will be discussed.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The Na62 Liquid Krypton Calorimeter Readout Module Published by Iop Publishing for Sissa the Na62 Liquid Krypton Calorimeter Readout Module Contents 1 Introduction 1 1.1 Na62 Detectors Layout 1 1.2 Na62 Trigger System 2

The NA62 experiment [1] at CERN SPS (Super Proton Synchrotron) accelerator will be focused on precision tests of the Standard Model via studies of ultra-rare decays of charged kaons. The high resolution Liquid Krypton (LKr) calorimeter of the former NA48 experiment [2], together with other detectors, will provide a photon-veto with hermetic coverage from zero out to large angles from the decay ...

متن کامل

Closed-Loop Compensation of the Quadrature Error in MEMS Vibratory Gyroscopes

In this paper, a simple but effective method for compensation of the quadrature error in MEMS vibratory gyroscope is provided. The proposed method does not require any change in the sensor structure, or additional circuit in the feedback path. The mathematical relations of the proposed feedback readout system were analyzed and the proposed solution assures good rejection capabilities. Based on ...

متن کامل

Recent Experimental Results from the NA62 Gigatracker Prototypes: an Hybrid Silicon Pixel Detector with 100 ps Time Resolution

G. Aglieri Rinellaa,V. Carassitic,A. Ceccuccia,E. Cortinad ,J. Daguina,G. Dellacasab,M. Fiorinia,P. Jarrona,J. Kaplona,A. Klugea,F. Marchettoa,E. Martind ,A. Mapellia, f ,G. Mazzab,M. Morela,M. Noya,G. Nüssled ,P. Petagnaa,L. Perktolda,F. Petruccic,e,A. Cotta Ramusinoc,P. Riedlera,A. Rivettib,R. Wheadonb aCERN, Geneva Switzerland,bINFN Torino, Italy,cINFN Ferrare, Italy,dUCL Louvain la Neuve, B...

متن کامل

Microfluidic cooling for detectors and electronics

Micro-channel cooling is gaining considerable attention as an alternative technique for cooling of high energy physics detectors and front-end electronics. This technology is being evaluated for future tracking devices, where material budget limitations are a major concern. It is currently under investigation as an option for the cooling of the NA62 Gigatracker silicon pixel detector, where a m...

متن کامل

The Trigger and DAQ system for the NA62 experiment

The main goal of the NA62 experiment is to measure the branching ratio of the K → πνν̄ decay, collecting O(100) events in two years of data taking. Efficient online selection of interesting events and loss-less readout at high rate will be key issues for such experiment. An integrated trigger and data acquisition system has been designed. Only the very first trigger stage will be implemented in ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2009