The panchromatic and multispectral (PMS) sensor is an optical imaging sensor aboard the Gao Fen-1 (GF-1) satellite. This work describes an approach to validate the calibration coefficients of the PMS sensors based on the image data of the Landsat 8 Operational Land Imager (OLI). Two image pairs, one obtained over the Dunhuang test site and the other over the Golmud test site, were used in this paper. Two spectral band adjustment factors (SBAF), given as the radiance SBAF and reflectance SBAF, were applied to correct the differences in the respective images caused by the relative spectral responses of the PMS sensor and OLI. Uncertainties in the SBAF values arising from atmospheric parameters and the absence of a measured ground spectrum were analyzed in this paper. The results show that the average relative differences of top-of-atmosphere radiance and reflectance values for each band between the PMS sensor and OLI images are 2%–5% for most bands, after SBAF correction with a measured ground spectrum or fitted spectrum. It is demonstrated that the OLI image can be used to validate the calibration coefficient of the PMS sensor, even if the image pairs are not imaged on the same day.
منابع مشابه
Radiometric Cross-Calibration of GF-4 in Multispectral Bands
The GaoFen-4 (GF-4), launched at the end of December 2015, is China’s first high-resolution geostationary optical satellite. A panchromatic and multispectral sensor (PMS) is onboard the GF-4 satellite. Unfortunately, the GF-4 has no onboard calibration assembly, so on-orbit radiometric calibration is required. Like the charge-coupled device (CCD) onboard HuanJing-1 (HJ) or the wide field of vie...
متن کاملRadiometric cross Calibration of Gaofen-1 WFV Cameras Using Landsat-8 OLI Images: A Simple Image-Based Method
WFV (Wide Field of View) cameras on-board Gaofen-1 satellite (gaofen means high resolution) provide unparalleled global observations with both high spatial and high temporal resolutions. However, the accuracy of the radiometric calibration remains unknown. Using an improved cross calibration method, the WFV cameras were re-calibrated with well-calibrated Landsat-8 OLI (Operational Land Imager) ...
متن کاملRadiometric Cross-Calibration of GF-4 PMS Sensor Based on Assimilation of Landsat-8 OLI Images
Earth observation data obtained from remote sensors must undergo radiometric calibration before use in quantitative applications. However, the large view angles of the panchromatic multispectral sensor (PMS) aboard the GF-4 satellite pose challenges for cross-calibration due to the effects of atmospheric radiation transfer and the bidirectional reflectance distribution function (BRDF). To addre...
متن کاملLandsat 8 Thermal Infrared Sensor Geometric Characterization and Calibration
The Landsat 8 spacecraft was launched on 11 February 2013 carrying two imaging payloads: the Operational Land Imager (OLI) and the Thermal Infrared Sensor (TIRS). The TIRS instrument employs a refractive telescope design that is opaque to visible wavelengths making prelaunch geometric characterization challenging. TIRS geometric calibration thus relied heavily on on-orbit measurements. Since th...
متن کاملRadiometric Cross Calibration of Landsat 8 Operational Land Imager (OLI) and Landsat 7 Enhanced Thematic Mapper Plus (ETM+)
This study evaluates the radiometric consistency between Landsat-8 Operational Land Imager (OLI) and Landsat 7 Enhanced Thematic Mapper Plus (ETM+) using cross calibration techniques. Two approaches are used, one based on cross calibration between the two sensors using simultaneous image pairs, acquired during an underfly event on 29–30 March 2013. The other approach is based on using time seri...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Remote Sensing
دوره 8 شماره
صفحات -
تاریخ انتشار 2016