Active motion artifact cancellation for wearable health monitoring sensors using collocated MEMS accelerometers
نویسندگان
چکیده
This paper presents an active noise cancellation technique for recovering wearable biosensor signals corrupted by bodily motion. A finger mounted photoplethysmograph (PPG) ring sensor with a collocated MEMS accelerometer is considered. The system by which finger acceleration disturbs PPG output is identified and a means of modeling this relationship is prescribed using either FIR or Laguerre models. This means of modeling motivates the use of a recursive least squares active noise cancellation technique using the MEMS accelerometer reading as an input for a FIR or Laguerre model. The model parameters are identified and tuned in real time to minimize the power of the recovered PPG signal. Experiments show that the active noise cancellation method can recover pulse information from PPG signals corrupted with up to 2G of acceleration with 85% improvement in mean squared error.
منابع مشابه
Motion Artifact Reduction for Wearable Photoplethysmogram Sensors Using Micro Accelerometers and Laguerre Series Adaptive Filters by Levi
The photoplethysmogram (PPG) is an extremely useful wearable sensing medical diagnostic tool. However, the PPG signal becomes highly corrupted when the wearer is in motion, rendering the measured signal useless. This thesis develops an adaptive motion artifact reduction scheme to recover the underlying physiologic information from the corrupted signal using a collocated accelerometer as a motio...
متن کاملArtifacts in wearable photoplethysmographs during daily life motions and their reduction with least mean square based active noise cancellation method
Signal distortion of photoplethysmographs (PPGs) due to motion artifacts has been a limitation for developing real-time, wearable health monitoring devices. The artifacts in PPG signals are analyzed by comparing the frequency of the PPG with a reference pulse and daily life motions, including typing, writing, tapping, gesturing, walking, and running. Periodical motions in the range of pulse fre...
متن کاملMotion-Artifact Resistant Design of Photoplethysmograph Ring Sensor for Driver Monitoring
Through extensive literature search, it has been found that there exists strong correlation between the Mental Workload of an automobile driver with his or her physiological measurements, especially the Heart Rate Variability (HRV) measurements. In order to make a driver's HRV monitoring on the road possible, a new photoplethysmograph (PPG) Ring Sensor prototype has been devised specifically fo...
متن کاملTesting of MEMS based Inertial Sensors
New technologies based on micro-technology, so called MEMS (Micro ElectroMechanical Systems), have been enabling many new products over the last ten years such as inkjet printers, displays or pressure sensors. Focusing on measurement of motion, MEMS inertial sensors such as accelerometers and gyroscopes, open new application fi elds for three big branches: Testing of MEMS based Inertial Sensors...
متن کاملDesign and Development of Heart Rate Monitoring Device with Reduction of Motion Artefact using 3-axis Accelerometer
There are various non-invasive heart rate monitoring devices available for monitoring & diagnosis of the patient. It has been observed that the final values of the device are altered by the motion. This paper overcome the problems related with variations in the health parameters due to the motion of the object by developing a viable device to catch human critical physiological parameters like h...