The Procedure Execution Manager and Its Application to Advanced Photon Source Operation
نویسنده
چکیده
The Procedure Execution Manager (PEM) combines a complete scripting environment for coding accelerator operation procedures with a manager application for executing and monitoring the procedures. PEM is based on Tcl/Tk, a supporting widget library, and the dp-tcl extension for distributed processing. The scripting environment provides support for distributed, parallel execution of procedures along with join and abort operations. Nesting of procedures is supported, permiting the same code to run as a top-level procedure under operator control or as a subroutine under control of another procedure. The manager application allows an operator to execute one or more procedures in automatic, semi-automatic, or manual modes. It also provides a standard way for operators to interact with procedures. A number of successful applications of PEM to accelerator operations have been made to date. These include start-up, shutdown, and other control of the positron accumulator ring (PAR), low-energy transport (LET) lines, and the booster rf systems. The PAR/LET procedures make nested use of PEM’s ability to run parallel procedures. There are also a number of procedures to guide and assist tune-up operations, to make accelerator physics measurements, and to diagnose equipment. Because of the success of the existing procedures, expanded use of PEM is planned.
منابع مشابه
From egg shell wastes (ESWs) into advanced materials: A rapid and simple synthesis of CaO/Ca2Fe2O5 as a novel nanocomposite-derived ESW biomaterial
AbstractESW as a natural byproduct, although non-hazardous and contains calcium, magnesium carbonate and protein, is commonly disposed in landfills without any pretreatment because it was traditionally useless. In this regards, we wish to report the synthesis of a novel CaO/Ca2Fe2O5 nanocomposite based on ESW. At the first, eggshell (ES) nanopowder was prepared by ball-milling. Then, the ...
متن کاملUWB Mixer improvement with Regulated Voltage Source
This paper presents a design of an UWB downconversion integrated CMOS resistive ring mixer with Linear Voltage Regulator (LVR), to supply required biasing voltages for the mixer section. The designed mixer circuit has been optimized for using in heart rate extraction system with microwave Doppler radar at 2.4GHz frequency. This mixer needs 2 DC bias voltages equal to 0.5 and 1 volts for its bes...
متن کاملOsteomyalgia and its Application in the Treatment of Orthopedic Lesions
The chiari pelvic Osteotomy deserves better Than the rather damnirtg description of"SalVage Procedure".Although it Cannot be regarded as a physiologic reconstructive Procedure because hyaline ,articular Cartilage is not brought over.the femoral head, it. nevertheless has unique advantages and specific indications. The Procedure is entlrely extra-articular, and the tissue" largely newl ne "that ...
متن کاملAn Operator Training Facility at the Advanced Photon Source*
The Advanced Photon Source (APS), a premier thirdgeneration synchrotron radiation source, presently operates in top-up mode during most user run time. During top-up mode, charge is injected into the storage ring at approximately 2-minute intervals to stabilize the stored beam current to within 0.1%. Top-up mode requires the dedicated use of the entire APS injector system, severely limiting time...
متن کاملنقش تکنولوژی در بهبود درمان سرطان
One major strategy, technology-driven improvement of treatment conformity in cancer treatment, including advanced image guidance, advanced charged particle therapy (CPT), and application of nanoparticles in hyperthermia, will enable further widening of the therapeutic window of cancer treatment in the era of precision medicine. The state of the art treatment in photon-therapy is advanced 3D...