Uncorrected wavefront error and visual performance during RGP wear in keratoconus.
نویسندگان
چکیده
PURPOSE To examine the relationship between uncorrected residual wavefront error and visual performance (VP) in rigid gas permeable (RGP) contact lens-wearing keratoconic eyes. METHODS Seven eyes from six subjects (six moderate, one severe) were studied (mean +/- SD age: 42.71 +/- 11.38 years). Significant corneal scarring was an exclusion criterion. Measurements were taken with RGP lenses in place. After pupil dilation, the VP measures of high contrast logMAR visual acuity (VA) and Pelli-Robson contrast sensitivity (PRCS) were measured through a 5-mm artificial pupil. Wavefront error was measured using a Shack-Hartmann wavefront sensor and calculated over 5 mm. For both VP and wavefront error, comparisons were made to previously collected normal values by calculating the interval encompassing 95% of normals, then reporting how many of the seven keratoconic eyes fell outside the normal interval. Additionally, second to sixth order aberrations were processed into four previously reported image quality metrics: root mean square of the wavefront (RMSw), root mean square of the slope (RMSs), average blur strength (Bave) and diameter containing 50% light energy (D50) and regressed against VP measures. RESULTS Five of seven keratoconic eyes fell outside the normal interval (-0.23 to 0.09) for VA and two of seven fell outside the normal interval (1.59 to 2.03) for PRCS. Five of seven keratoconic eyes fell outside the normal interval (0.07 to 0.35 microm) for total higher order RMS. Linear regressions demonstrated relationships between both VA and PRCS and the image quality metrics RMSw, D50, RMSs, and Bave with R values for VA = 0.30, 0.30, 0.47, 0.62, and PRCS = 0.21, 0.15, 0.45, 0.75 respectively. CONCLUSIONS VP in RGP-wearing keratoconic eyes is reduced and higher order wavefront aberrations are elevated compared to normals. Metrics of retinal image quality demonstrate a relationship between keratoconic VP and residual wavefront aberrations. This relationship suggests developing corrections that more completely correct aberrations may improve visual performance in keratoconus.
منابع مشابه
Keratoconic Bi - aspheric Contact Lenses
Aim: This observational clinical case series examined patients with keratoconus (KC) fit with keratoconic bi-aspheric (KBA) lenses to assess visual acuity (VA), wavefront aberrations, physiological fitting, subjective comfort, and manufacturer’s fitting guidelines. Materials and methods: Seven adult patients (11 eyes, four females, mean age: 34.15 ± 14.12) with nipple cones from the Hadassah Ac...
متن کاملVisual rehabilitation with new-age rigid gas-permeable scleral contact lenses--a case series.
INTRODUCTION Primary ectatic corneal diseases usually require rigid gas-permeable (RGP) corneal contact lens wear for visual rehabilitation. As the disease progresses, it becomes increasingly difficult to fit these lenses. RGP scleral contact lenses now provide another treatment option before resorting to surgery. CLINICAL PICTURE Two patients with pellucid marginal degeneration and one with ...
متن کاملTreatment of visual problems after intracorneal ring implantation
PURPOSE To report the effect of wavefront-guided photorefractive keratectomy and corneal collagen cross-linking (CXL) on visual problems after Ferrara ring segment placement. MATERIALS AND METHODS A 32-year-old male patient was treated with a Ferrara ring segment for keratoconus. One year later, the ring was removed due to severe glare complaints. After 6 months, wavefront-guided photorefract...
متن کاملCorneal aberration changes after rigid gas permeable contact lens wear in keratokonic patients
PURPOSE To determine the short-term effect of rigid gas permeable (RGP) contact lenses on corneal aberrations in keratoconic patients. METHOD Sixteen keratoconic eyes with no history of RGP lens wear were included. They all had corneal aberrometry using Pentacam, and different aberration indices of the anterior and posterior surfaces of the cornea were measured before and 3 months after fitti...
متن کاملShort-term corneal changes with gas-permeable contact lens wear in keratoconus subjects: a comparison of two fitting approaches.
PURPOSE To evaluate changes in anterior corneal topography and higher-order aberrations (HOA) after 14-days of rigid gas-permeable (RGP) contact lens (CL) wear in keratoconus subjects comparing two different fitting approaches. METHODS Thirty-one keratoconus subjects (50 eyes) without previous history of CL wear were recruited for the study. Subjects were randomly fitted to either an apical-t...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Optometry and vision science : official publication of the American Academy of Optometry
دوره 84 6 شماره
صفحات -
تاریخ انتشار 2007