Uncertainty associated with the gravimetric measurement of particulate matter concentration in ambient air.

نویسندگان

  • Ronald E Lacey
  • William Brock Faulkner
چکیده

UNLABELLED This work applied a propagation of uncertainty method to typical total suspended particulate (TSP) sampling apparatus in order to estimate the overall measurement uncertainty. The objectives of this study were to estimate the uncertainty for three TSP samplers, develop an uncertainty budget, and determine the sensitivity of the total uncertainty to environmental parameters. The samplers evaluated were the TAMU High Volume TSP Sampler at a nominal volumetric flow rate of 1.42 m3 min(-1) (50 CFM), the TAMU Low Volume TSP Sampler at a nominal volumetric flow rate of 17 L min(-1) (0.6 CFM) and the EPA TSP Sampler at the nominal volumetric flow rates of 1.1 and 1.7 m3 min(-1) (39 and 60 CFM). Under nominal operating conditions the overall measurement uncertainty was found to vary from 6.1x10(-6) g m(-3) to 18.0x10(-6) g m(-3), which represented an uncertainty of 1.7% to 5.2% of the measurement. Analysis of the uncertainty budget determined that three of the instrument parameters contributed significantly to the overall uncertainty: the uncertainty in the pressure drop measurement across the orifice meter during both calibration and testing and the uncertainty of the airflow standard used during calibration of the orifice meter. Five environmental parameters occurring during field measurements were considered for their effect on overall uncertainty: ambient TSP concentration, volumetric airflow rate, ambient temperature, ambient pressure, and ambient relative humidity. Of these, only ambient TSP concentration and volumetric airflow rate were found to have a strong effect on the overall uncertainty. The technique described in this paper can be applied to other measurement systems and is especially useful where there are no methods available to generate these values empirically. IMPLICATIONS This work addresses measurement uncertainty of TSP samplers used in ambient conditions. Estimation of uncertainty in gravimetric measurements is of particular interest, since as ambient particulate matter (PM) concentrations approach regulatory limits, the uncertainty of the measurement is essential in determining the sample size and the probability of type II errors in hypothesis testing. This is an important factor in determining if ambient PM concentrations exceed regulatory limits. The technique described in this paper can be applied to other measurement systems and is especially useful where there are no methods available to generate these values empirically.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Research Papers Involving the TSI DustTrak Aerosol Monitor - Application Note ITI-079

Particulate air pollution, specifically the fine particle fraction (PM2.5), has been associated with increased cardiopulmonary morbidity and mortality in general population studies. Occupational exposure to fine particulate matter can exceed ambient levels by a large factor. Due to increased interest in the health effects of particulate matter, many particle sampling methods have been developed...

متن کامل

The Study of PM2.5 and PM10 Particulate Matter Concentration in the Ambient Air Pollution of Khash Cement Company (Sistan and Balouchestan Province)

Introduction: Environmental pollution also increased by the advancement of technology and the application of industries in human life. Air pollution is one of the major contaminations in the human environment which causes many acute and chronic diseases. This study was conducted to investigate the contamination of PM2.5 and PM10 particles in Khash Cement Company in Sistan and Baluchestan provin...

متن کامل

Determination of Polycyclic Aromatic Hydrocarbons in Ambient Urban Air

Polycyclic aromatic hydrocarbons (PAHS) have been determined in the atmosphere of Isfahan, Iran. Airborne particulate matter was sampled using a high-volume air sampler at roof-top level (~6m). Extraction of PAHS from airborne particulate matter has been performed using SFE system and the relationship between the extraction temperature and the recovery of PAHS</su...

متن کامل

Trend of ambient air particulate matter with aerodynamic diameter of 2.5 μm and smaller in Zahedan city in 2018-2019

Background and Objective: Air pollution is one of the most important environmental risk factors that exposure to it can cause many acute and chronic effects on human health. Some regions of Iran, especially the western, southern and southeastern provinces of the country, have been affected with dust storm for years. Studies on the frequencies of dusty days in the country show that central pits ...

متن کامل

Spatial Analysis and Source Identification of Particulate Matter (PM10) in Yazd City

Introduction: The aim of this study was to spatial analysis of PM10 concentrations in the ambient air of Yazd in two seasons, and the zoning by using Kriging interpolation method. Finally, different factors affecting the concentrations of PM10 are marked and standards have been investigated Material and methods: The measurement of PM10 particulates was performed by the monitoring device HAZ-...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of the Air & Waste Management Association

دوره 65 7  شماره 

صفحات  -

تاریخ انتشار 2015