Heat Release Rate of an Open Kitchen Fire of Small Residential Units in Tall Buildings
نویسندگان
چکیده
In the Far East, many small units of residential buildings over 200 m tall are fitted with open kitchens. Fire safety provisions of these kitchens are determined by performance-based design (PBD). In most PBD projects, only the spread of smoke from the kitchen fire to the outside was studied. However, a fire load survey in Hong Kong indicated that large quantities of combustibles are stored in residential units. Cooking oil was found to be ignited easily even when using induction cookers. The burning of all combustibles in a big post-flashover fire needs to be studied. A database of heat release rates for local combustible products is not yet available. Estimations are based on very crude assumptions of low radiative heat flux in most of the PBD projects, and they are not supported by fullscale burning tests. In this paper, heat release rate for an open kitchen fire will be studied by the principle of superposition. The important issues in the estimation of heat release rate will be addressed and discussed. An example calculation of achieving low values of heat release rate will also be illustrated. The authority having jurisdiction is recommended to review such approach.
منابع مشابه
Application of Nonlinear Dynamics in Studying Flashover Fire in a Small Open Kitchen
Open kitchen designs are found in small units in tall residential buildings of Asian-Oceania regions for better space utilization. As many combustibles are stored in small residential units, fire originated in the open kitchen can grow and spread fast. Consequently, flashover can occur to give a big fire and result in severe casualties and property damage. Nonlinear dynamics can be applied to p...
متن کاملFire Safety Concern on Open Kitchen in Small Residential Units of Tall Buildings
Open kitchens have been designed for many small residential units in tall buildings in Southeast Asia. This open design, without enclosing the kitchen with fire resisting walls has failed to comply with building fire safety codes in places like Hong Kong. Performance-based design was adopted to determine fire safety provisions. Gas cookers with flames are not allowed. Additional fire protection...
متن کاملPerformance assessment of a SOFC cogeneration system for residential buildings located in eastern Iran
It is expected that residential units may replace traditional heat and power production systems with cogeneration ones. Among the different cogeneration systems, fuel cell based systems are a suitable choice due to their high efficiency, high power density, low emission and low noise. In this paper, a cogeneration system based on solid oxide fuel cells is examined. The system, including the f...
متن کاملمدل فنی- اقتصادی سیستمهای Micro CHP با روشهای عملکردی مختلف
The growing worldwide demand for less polluting forms of energy has led to a renewed interest in the use of micro combined heat and power (CHP) technologies in the residential sector. The operation of micro CHP system results in simultaneous production of heat and power in a single household based on small energy conversion units. The heat produced may be used for space and water heating and po...
متن کاملSolar Radiation and Orientation of Buildings: Case of Residential Buildings in Isfahan
Climatic conditions have a significant impact on the energy consumption of buildings. Also check the angle of the solar radiation on buildings and controlling the amount of heat absorbed on building shell during the year have significant impact on building energy efficiency. The aim of this study was to investigate the effect of orientation of the building on the energy consumption and to this...
متن کامل