Fluid-modulated bipolar radiofrequency ablation: an ex-vivo evaluation study.
نویسندگان
چکیده
BACKGROUND The effect of radiofrequency ablation (RFA) can be modulated by fluid injection. PURPOSE To evaluate the potential of different fluids to modulate the effect of bipolar RFA in an ex-vivo liver model. MATERIAL AND METHODS A bipolar RFA system with an internally cooled needle-shaped applicator (20-mm active tip) was used to induce coagulation lesions in ex-vivo porcine liver. Prior to the ablation procedure, 1-ml samples of seven different fluids were injected (0.9% saline, gadopentetate dimeglumine, ioxithalamate, 10% hydroxyethyl starch, 5% glucose, 95% ethanol, distilled water). Each fluid was used for five RF ablations. During the procedure, applied energy, impedance, and time were recorded. Additionally, temperature was measured at a fixed distance of 0.5 and 1.0 cm from the RF probe. Generator output was set to 20 W, as recommended by the vendor. Five ablation procedures without fluid injection served as the reference standard. The lesion diameters were measured, and volume and an efficiency index (coagulation volume/procedure duration) calculated and compared (ANOVA, Student-Newman-Keuls test). RESULTS In comparison to the reference standard, fluid injection resulted in an enlargement of mean coagulation volume for all fluids. In comparison to RF ablation alone (1.42+/-0.33 cm(3)), significant increase (P<0.001) of lesion size was found using gadopentetate dimeglumine, hydroxyethyl starch, glucose, and ethanol. The largest lesions were generated using preinjection of hydroxyethyl starch. Most energy could be applied after injection of glucose. Comparing the efficiency index, no statistically significant differences were found. CONCLUSION Besides the modulation of the electrical conductivity, the increase in thermal conductivity also contributes to the enhancement of RFA by the injection of the tested fluids. Further studies are needed to evaluate this effect for larger injection volumes under in-vivo conditions.
منابع مشابه
Bipolar radiofrequency ablation of the kidney: comparison with monopolar radiofrequency ablation.
PURPOSE We report initial ex vivo and in vivo studies using bipolar radiofrequency (RF) ablation of porcine kidneys. An internal ground electrode is positioned in the kidney opposite the RF electrode, resulting in ablation of all the intervening renal tissue. MATERIALS AND METHODS Ex vivo preparations of 10 porcine kidneys were perfused continuously with Ringer's solution and treated with eit...
متن کاملEx vivo evaluation of a bipolar application concept for radiofrequency ablation.
BACKGROUND Bipolar radiofrequency ablation (RFA) can avoid complications such as thermal tissue damage, a possible consequence of monopolar RFA. However, basic studies about the dosage/effect relationship of bipolar systems are missing. This is systematic research on ex vivo beef livers to find which capacity parameters produce high energy in the tissue and achieve large lesion volumes. MATER...
متن کاملBipolar and multipolar radio frequency ablation with resistance controlled power output: standardized ex vivo kidney tissue evaluation.
PURPOSE We investigated a newly developed bipolar and multipolar RF ablation system with an internally cooled electrode and resistance controlled power output in a standardized model of perfused ex vivo kidney tissue. MATERIALS AND METHODS RF energy was applied at different power levels (20, 30 and 60 W) for 1, 3, 5 and 9 minutes. Each treatment parameter was repeated 5 times. For the 20/30 W...
متن کاملNo-Touch Radiofrequency Ablation: A Comparison of Switching Bipolar and Switching Monopolar Ablation in Ex Vivo Bovine Liver
OBJECTIVE To evaluate the feasibility, efficiency, and safety of no-touch switching bipolar (SB) and switching monopolar (SM) radiofrequency ablation (RFA) using ex vivo bovine livers. MATERIALS AND METHODS A pork loin cube was inserted as a tumor mimicker in the bovine liver block; RFA was performed using the no-touch technique in the SM (group A1; 10 minutes, n = 10, group A2; 15 minutes, n...
متن کاملHistopomorphic Evaluation of Radiofrequency Mediated Débridement Chondroplasty
The use of radiofrequency devices has become widespread for surgical ablation procedures. When ablation devices have been deployed in treatment settings requiring tissue preservation like débridement chondroplasty, adoption has been limited due to the collateral damage caused by these devices in healthy tissue surrounding the treatment site. Ex vivo radiofrequency mediated débridement chondropl...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Acta radiologica
دوره 49 3 شماره
صفحات -
تاریخ انتشار 2008