A prospective study of carbon dioxide digital subtraction versus standard contrast arteriography in the detection of endoleaks in endovascular abdominal aortic aneurysm repairs.

نویسندگان

  • S Grace Huang
  • Karen Woo
  • John M Moos
  • Sukgu Han
  • Wesley K Lew
  • Alex Chao
  • Ann Hamilton
  • Christian Ochoa
  • Douglas B Hood
  • Vincent L Rowe
  • Fred A Weaver
چکیده

BACKGROUND The objective of this study is to compare intraoperative endoleak detection by carbon dioxide digital subtraction angiography (CO(2)-DSA) during endovascular aortic aneurysm repair (EVAR) with standard iodinated contrast angiography (ICA). METHODS Between 2006 and 2010, 76 patients with abdominal aortic aneurysms undergoing EVAR were enrolled in a prospective study. After EVAR, both an ICA and CO(2)-DSA completion study were performed. Two blinded vascular surgeons who were not involved with the EVAR separately interpreted the ICA and CO(2)-DSA results for the presence or absence of an endoleak. Identified endoleaks were classified by types. A third, "tie-breaker" blinded observer was used to resolve differences in interpretations. The sensitivity, specificity, negative predictive value, and positive predictive value were calculated for the ability of CO(2)-DSA to detect endoleaks. Cohen's κ statistic was used to assess interobserver agreement between the 2 initial interpreting surgeons. RESULTS Of the 76 patients undergoing EVAR, 66 were men with average age of 76 years, a mean aneurysm size of 5.8 cm (range, 4-10 cm), and creatinine of 1 (standard deviation, 0.33). ICA identified 35 type I and 15 type II endoleaks, respectively, while CO(2)-DSA identified 40 type I and 10 type II endoleaks. Overall, CO(2)-DSA had a sensitivity of 0.84, specificity of 0.72, positive predictive value of 0.86, and negative predictive value of 0.69 of intraoperative endoleak detection, with respect to ICA as the criterion standard. The interobserver κ between surgeons for ICA was 0.56, for detection of any endoleak or type I endoleak with CO(2)-DSA was 0.58, and for detection of type II endoleak with CO(2)-DSA was 0.29. CONCLUSIONS Interobserver agreement for the detection of endoleaks is superior with ICA compared to CO(2)-DSA. However, the sensitivity for detecting any endoleak and both the sensitivity and specificity for detecting type I endoleaks using CO(2)-DSA are acceptable. For detecting type II endoleaks using CO(2)-DSA, the sensitivity and positive predictive value are poor. Compared to ICA, CO(2)-DSA provides adequate images for endoleak detection during EVAR and is an acceptable alternative to ICA in patients at risk for contrast-related nephrotoxicity.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Carbon Dioxide Angiography: Scientific Principles and Practice

Carbon dioxide (CO2) is a colorless, odorless gas which occurs naturally in the atmosphere and human body. With the advent of digital subtraction angiography, the gas has been used as a safe and useful alternative contrast agent in both arteriography and venography. Because of its lack of renal toxicity and allergic potential, CO2 is a preferred contrast agent in patients with renal failure or ...

متن کامل

Imaging Surveillance following Endovascular Aneurysm Repair.

Endoleaks are unique complications of endovascular aneurysm repair (EVAR) that necessitate lifelong imaging surveillance for the patient. Several imaging modalities may be used to monitor the patient for endoleaks and other complications related to the stent graft. At present, computed tomographic angiography remains the gold standard for the detection of endoleaks. Other modalities that can be...

متن کامل

Frequency of Complications Following Endovascular Repair of Abdominal Aortic Aneurysm in Tehran Sina Hospital, 2011-2019

 Background and purpose: Abdominal aortic aneurysms (AAA) is a localized enlargement of infrarenal abdominal aorta. Endovascular aneurysm repair (EVAR) is a surgical method introduced for AAA repair. This study, for the first time in Iran, investigated the complications and mortality rate associated with EVAR.  Materials and methods: In this cross-sectional study, medical records were reviewed...

متن کامل

Duplex ultrasound and computed tomography angiography in the follow-up of endovascular abdominal aortic aneurysm repair: a comparative study*

OBJECTIVE To compare duplex ultrasound and computed tomography (CT) angiography in terms of their performance in detecting endoleaks, as well as in determining the diameter of the aneurysm sac, in the postoperative follow-up of endovascular abdominal aortic aneurysm repair. MATERIALS AND METHODS This was a prospective study involving 30 patients who had undergone endovascular repair of infrar...

متن کامل

An Aortoenteric Fistula Arising after Endovascular Management of a Mycotic Abdominal Aortic Aneurysm Complicated with a Psoas Abscess

Mycotic aortic aneurysms account for 1–3% of all aortic aneurysms. The management of this disease is controversial. Since open surgical repair is associated with high morbidity and mortality rates, endovascular aneurysm repair is an alternative treatment method with promising early and midterm outcomes, although its long-term durability is unknown.Secondary aortoenteric fistulas may occur iatro...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Annals of vascular surgery

دوره 27 1  شماره 

صفحات  -

تاریخ انتشار 2013