Strategies to estimate the characteristics of 24-hour IOP curves of treated glaucoma patients during office hours
نویسندگان
چکیده
BACKGROUND It is known that office-hour measurements might not adequately estimate IOP mean, peaks and fluctuations in healthy subjects. The purpose of the present study is to verify whether office-hour measurements in patients in different body positions can estimate the characteristics of 24-hour intraocular pressure (IOP) in treated POAG patients. METHODS The 24-hour IOP curves of 70 eyes of 70 caucasian patients with treated glaucoma were analyzed. Measurements were taken at 9 AM; 12, 3, 6, and 9 PM; and 12, 3, and 6 AM, both in the supine (TonoPen XL) and sitting (Goldmann tonometer) positions. The ability of five strategies to estimate IOP mean, peak and fluctuation was evaluated. Each method was analyzed both with regression of the estimate error on the real value and with "hit or miss" analysis. RESULTS The least biased estimate of the Peak IOP was obtained using measurements from both supine and sitting positions, also yielding the highest rate of correct predictions (which was significantly different from 3 of the remaining 4 strategies proposed, p < 0.05). Strategies obtained from the combination of supine, sitting and peak measurements resulted to be least biased for the Mean IOP and the IOP Fluctuation estimate, but all strategies were not found significantly different in terms of correct prediction rate (the only significant difference being between the two strategies based on sitting or supine measurements only, with the former being the one with the highest correct prediction rate). CONCLUSIONS The results of this study remark the concept that IOP is a dynamic parameter and that intensive measurement is helpful in determining its characteristics. All office-hour strategies showed a very poor performance of in correctly predicting the considered parameters within the thresholds used in this paper, all scoring a correct prediction rate below 52%.
منابع مشابه
The circadian curve of intraocular pressure: can we estimate its characteristics during office hours?
PURPOSE To verify whether office-hour measurements in patients in different body positions can estimate the characteristics of 24-hour intraocular pressure (IOP). METHODS The 24-hour IOP curves of 29 healthy subjects (10 young adults, 19 elderly) and 30 patients with untreated glaucoma were analyzed. Measurements were taken at 9 AM; 12, 3, 6, and 9 PM; and 12, 3, and 6 AM, both in the supine ...
متن کاملSelf-Monitoring of Intraocular Pressure Outside of Normal Office Hours Using Rebound Tonometry: Initial Clinical Experience in Patients With Normal Tension Glaucoma.
PURPOSE To determine the value and accuracy of 24-hour intraocular pressure (IOP) phasing using Icare ONE rebound tonometry (RTONE), in subjects with normal tension glaucoma (NTG). METHODS Eighteen consecutive patients with treated NTG were studied, all subjects had undergone 24-hour IOP phasing during a 1-year period. Each patient had daytime (08:00 to 16:00) IOP phasing with Goldmann applan...
متن کاملShort-Term Reproducibility of Twenty-Four-Hour Intraocular Pressure Curves in Untreated Patients with Primary Open-Angle Glaucoma and Ocular Hypertension
PURPOSE To assess the short-term day-to-day reproducibility of 24-hour intraocular pressure (IOP) curves in various respects in untreated primary open-angle glaucoma (POAG) and ocular hypertension (OHT) patients. METHODS 47 subjects with POAG and 34 subjects with OHT underwent IOP measurements every 2 hours in both eyes for consecutive 48 hours by a non-contact tonometer (NCT). IOP values at ...
متن کاملThe relationship between diurnal variations in intraocular pressure measurements and central corneal thickness and corneal hysteresis.
PURPOSE To examine the relationship between office-hour changes in IOP, measured with the Goldmann applanation tonometer (GAT) and dynamic contour tonometer (DCT), and the corneal characteristics central corneal thickness (CCT) and corneal hysteresis (CH). METHODS Sixty-two eyes of 62 untreated normal subjects and patients with untreated glaucoma had IOP measurements performed with the GAT (m...
متن کاملDetecting IOP Fluctuations in Glaucoma Patients
Lowering intraocular pressure (IOP) remains the guiding principle of glaucoma management. Although IOP is the only treatable risk factor, its 24-hour behavior is poorly understood. Current glaucoma management usually relies on single IOP measurements during clinic hours, even though IOP is a dynamic parameter with rhythms dependent on individual patients. It has further been shown that most gla...