Developments for a New Spectral Irradiance Scale at the National Institute of Standards and Technology
نویسنده
چکیده
Recent developments for a new spectral irradiance scale realization at the National Institute of Standards and Technology have been targeted to reduce the present relative expanded uncertainties of 0.67 % to 4.34 % (coverage factor of k = 2 and thus a 2 standard deviation estimate) in the spectral irradiance scale to 0.17 % for the range from 350 nm to 1100 nm. To accomplish this goal, a suite of filter radiometers calibrated using NIST's high accuracy cryogenic radiometer have been used to measure the temperature of a high-temperature black-body. A comparison of the filter radiometer calibrations with the spectral irradiance scale along with an evaluation of the black-body calibration technique have been performed. With the aid of a monochromator, the calibrated filter radiometers will then be utilized to calibrate primary and secondary spectral irradiance standard lamps at NIST.
منابع مشابه
Realization of the National Institute of Standards and Technology detector-based spectral irradiance scale.
A detector-based spectral irradiance scale has been realized at the National Institute of Standards and Technology (NIST). Unlike the previous NIST spectral irradiance scales, the new scale is generated with filter radiometers calibrated for absolute spectral power responsivity traceable to the NIST high-accuracy cryogenic radiometer instead of with the gold freezing-point blackbody. The calibr...
متن کاملTechnical guide to Set Up a Spectral Solar Direct Normal Irradiance Permanent Station: Study Area- Hannover, Germany
The spectral Direct Normal Irradiance (SDNI) is a basic radiometric quantity from which many other quantities can be derived. It provides not only information about the spectral and distribution of the direct solar radiation reaching a particular location. Accurate knowledge about the spectral direct irradiance shall enable us to gain new scientific results in the: determination of cloud effect...
متن کاملThe 1996 North American Interagency Intercomparison of Ultraviolet Monitoring Spectroradiometers
Concern over stratospheric ozone depletion has prompted several government agencies in North America to establish networks of spectroradiometers for monitoring solar ultraviolet irradiance at the surface of the Earth. To assess the ability of spectroradiometers to accurately measure solar ultraviolet irradiance, and to compare the results between instruments of different monitoring networks, th...
متن کاملRealization of the NIST Total Spectral Radiant Flux Scale
The total spectral radiant flux scale has been realized at National Institute of Standards and Technology using a goniospectroradiometer for the 360 nm to 800 nm region. The construction of the goniospectroradiometer and results of the scale realization as well as the uncertainty budget are presented. Introduction. There are increasing needs for total spectral radiant flux standards, which are ...
متن کاملUltraviolet Spectral Irradiance Scale Comparison: 210 nm to 300 nm
Comparison of the irradiances from a number of ultraviolet spectral irradiance standards, based on different physical principles, showed agreement to within their combined standard uncertainties as assigned to them by NIST. The wavelength region of the spectral irradiance comparison was from 210 nm to 300 nm. The spectral irradiance sources were: an electron storage ring, 1000 W quartz-halogen ...
متن کامل