Influence of attachment systems on load transfer of an implant-assisted maxillary overdenture.
نویسندگان
چکیده
PURPOSE This photoelastic study compared the load transfer characteristics of 2 retention mechanisms in an implant-assisted overdenture prosthesis. MATERIALS AND METHODS Four implants were incorporated into a photoelastic model of a moderately resorbed edentulous human maxilla. Two retention mechanisms were studied by changing components on the same model and the palateless overdenture. The retention mechanisms studied were bar splint with anterior clip and distal resilient attachments, and solitary ball/O-ring attachments. Loads, ranging from 1.4 to 14.4 kg, were applied to the palatal incline of central incisors and buccal incline of premolars with and without balancing contacts. Stresses developed around all the implants under each loading condition were photographed in the field of a circular polariscope. RESULTS With both retention mechanisms, protrusive and laterotrusive loads without balancing contacts caused instability of the overdenture, producing minimal stress around the implants in the supporting structure. High intensity stresses indicating intrusion of the posterior implants were noted when the bar/distal resilient attachment overdenture had balancing contacts for protrusive and laterotrusive loads. The posterior implants of ball/O-ring attachment overdenture exhibited high intensity stresses indicating not only intrusion, but also bending, when the occlusion was balanced. CONCLUSIONS Balanced occlusion was required in both retention mechanisms for stability of the implant-assisted overdenture when clinically acceptable loads were applied. The protrusive and laterotrusive loads were not distributed equitably in either mechanism, since highest stresses occurred at the posterior implants.
منابع مشابه
Comparison of the Effect of Ball and Bar Attachment Designs on Retention and Stability of Mandibular Implant-Supported Overdentures
Objectives: The present study evaluated the effect of bar and ball attachment designs on retention and stability of a mandibular overdenture supported by four implants. Methods: An edentulous mandibular acrylic resin model with four implants in the anterior part of the ridge (A, B, D and E) was fabricated. A metal framework simulating the overdenture was also fabricated. Totally, 30...
متن کاملComparison of stresses transferred to the implant supported overdentures with bar, ball and zaag attachments through photoelasticity
Comparison of stresses transferred to the implant supported overdentures with bar, ball and zaag attachments through photoelasticity Dr. A. Saboori* - Dr. Gh. Esfahanizade** - Dr. M. Ejlali*** *- Assistant Professor of Prosthodontics Dept. - Faculty of Dentistry – Shaheed Beheshti University of Medical Sciences. **- Assistant Professor of Prosthodontics Dept. - Faculty of Dentistry – Tehran Isl...
متن کاملFinite element analysis on stress distribution of maxillary implant-retained overdentures depending on the Bar attachment design and palatal coverage
PURPOSE The purpose of this study was to determine the effect of anchorage systems and palatal coverage of denture base on load transfer in maxillary implant-retained overdenture. MATERIALS AND METHODS Maxillary implant-retained overdentures with 4 implants placed in the anterior region of edentulous maxilla were converted into a 3-D numerical model, and stress distribution patterns in implan...
متن کاملMaxillary Implant-Supported Over-Denture, Role of Attachment Selection on Treatment Success Rate: A Literature Review
Objectives Maxillary implant-supported over-denture is a suitable treatment where conventional denture cannot be used. Few studies are available on maxillary over-denture while more are available on mandibular over-denture with no literature referring to attachment selection in maxillary over-dentures. The objective of this literature review was to see attachment selection strategies in maxill...
متن کاملEffect of Abutment Height Difference on Stress Distribution in Mandibular Overdentures: A Three-Dimensional Finite Element Analysis
Background and Aim: Implant-supported overdentures are a treatment option for edentulous patients. One of the important factors in determining the prognosis of overdenture treatment is to control the distribution of stress in the implant-bone and attachment complex. This study assessed the effect of implant abutment height difference on stress distribution in mandibular overdentures. Materials...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of prosthodontics : official journal of the American College of Prosthodontists
دوره 13 4 شماره
صفحات -
تاریخ انتشار 2004