Validation of six years of TES tropospheric ozone retrievals with ozonesonde measurements: implications for spatial patterns a d temporal stability in the bias
نویسنده
چکیده
In this analysis, Tropospheric Emission Spectrometer (TES) V004 nadir ozone (O3) profiles are validated with more than 4400 coinciding ozonesonde measurements taken across the world from the World Ozone and Ultraviolet Radiation Data Centre (WOUDC) during the period 2005–2010. The TES observation operator was applied to the sonde data to ensure a consistent comparison between TES and ozonesonde data, i.e. without the influence of the a priori O3 profile needed to regulate the retrieval. Generally, TES V004 O3 retrievals are biased high by 2–7 ppbv (7–15 %) in the troposphere, consistent with validation results from earlier studies. Because of two degrees of freedom for signal in the troposphere, we can distinguish between upper and lower troposphere mean biases, respectively ranging from −0.4 to +13.3 ppbv for the upper troposphere and +3.9 to +6.0 ppbv for the lower troposphere. Focusing on the 464 hPa retrieval level, broadly representative of the free tropospheric O3, we find differences in the TES biases for the tropics (+3 ppbv, +7 %), sub-tropics (+5 ppbv, +11 %), and northern (+7 ppbv, +13 %) and southern mid-latitudes (+4 ppbv, +10 %). The relatively long-term record (6 yr) of TES–ozonesonde comparisons allowed us to quantify temporal variations in TES biases at 464 hPa. We find that there are no discernable biases in each of these latitudinal bands; temporal variations in the bias are typically within the uncertainty of the difference between TES and ozonesondes. Establishing these bias patterns is important in order to make meaningful use of TES O3 data in applications such as model evaluation, trend analysis, or data assimilation.
منابع مشابه
Estimating the summertime tropospheric ozone distribution over North America through assimilation of observations from the Tropospheric Emission Spectrometer
[1] We assimilate ozone and CO retrievals from the Tropospheric Emission Spectrometer (TES) for July and August 2006 into the GEOS-Chem and AM2-Chem models. We show that the spatiotemporal sampling of the TES measurements is sufficient to constrain the tropospheric ozone distribution in the models despite their different chemical and transport mechanisms. Assimilation of TES data reduces the me...
متن کاملValidation of Tropospheric Emission Spectrometer (TES) measurements of the total, stratospheric, and tropospheric column abundance of ozone
[1] The Tropospheric Emission Spectrometer (TES) is an infrared, high-resolution Fourier transform spectrometer which was launched onboard NASA’s Aura satellite in 2004 and is providing global, vertically resolved measurements of ozone in the troposphere. TES version 2 (V002) data profiles have been validated in the troposphere and lower stratosphere by way of comparison to ozonesondes and airc...
متن کاملCapturing time and vertical variability of tropospheric ozone: A study using TES nadir retrievals
[1] In this paper, the vertical resolution for Tropospheric Emission Spectrometer (TES) nadir ozone retrievals is established and is used to assess the ability of TES to capture time variations of ozone in the troposphere. This characterization is based on retrievals of ozone using simulated radiances generated from ozonesonde profiles taken over Bermuda from 14 April to 25 May 1993. To that en...
متن کاملA multi-sensor upper tropospheric ozone product (MUTOP) based on TES ozone and GOES water vapor: validation with ozonesondes
Accurate representation of ozone in the extratropical upper troposphere (UT) remains a challenge. However, the implementation of hyper-spectral remote sensing using satellite instruments such as the Tropospheric Emission Spectrometer (TES) provides an avenue for mapping ozone in this region, from 500 to 300 hPa. As a polar orbiting satellite TES observations are limited, but in this paper they ...
متن کاملOzone correlations between mid-tropospheric partial columns and the near-surface at two mid-atlantic sites during the DISCOVER-AQ campaign in July 2011
The current network of ground-based monitors for ozone (O3) is limited due to the spatial heterogeneity of O3 at the surface. Satellite measurements can provide a solution to this limitation, but the lack of sensitivity of satellites to O3 within the boundary layer causes large uncertainties in satellite retrievals at the near-surface. The vertical variability of O3 was investigated using ozone...
متن کامل