Determination of norfloxacin using a terbium-sensitized electrogenerated chemiluminescence method.

نویسندگان

  • Shi-Lv Chen
  • Yu Liu
  • Hui-Chun Zhao
  • Lin-Pei Jin
  • Zhong-Lun Zhang
  • Yan-Zhen Zheng
چکیده

A simple electrogenerated chemiluminescence (ECL) analysis method for the determination of norfloxacin (NFLX) is reported. It is based on ECL produced by Na(2)SO(3), which is sensitized by the Tb-NFLX complex. The relative ECL intensity of the Tb(3+)-NFLX-Na(2)SO(3) system is proportional to the amount of NFLX. The optimized experimental conditions were investigated. The linear range and detection limit for NFLX were 1.0 x 10(-10)-8.0 x 10(-7) mol/L and 2.8 x 10(-11) mol/L, respectively. This method was successfully applied to the determination of NFLX in a capsule. NFLX in urine can be directly detected without pretreatment or separation.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Terbium Sensitized Chemiluminescence Method for the Determination of Rabeprazole -Application to Pharmaceutical Analysis and Dissolution Studies

A simple and sensitive chemiluminescence-based method was established for the determination of rabeprazole.The proposed method was based on the enhancing effect of rabeprazole on Ce(IV)-Na2SO3 -Tb(III) chemiluminescence reaction. A possible mechanism was discussed for chemiluminescence system by studying UV-Vis, fluorescence and chemiluminescence spectra. The effects of va...

متن کامل

Determination of Methotrexate in Biological Fluids and a Parenteral Injection Using Terbium-Sensitized Method

A new sensitive, simple and rapid method for determination of methotrexate (MTX) was developed based on quenching effects of MTX on the fluorescence intensity of Tb3+-1,10-phenanthroline complex. The fluorescence intensity was measured with excitation wavelength of 300 nm and emission wavelength of 545 nm and the quenched fluorescence intensity is proportional to the concentration of MTX in Tris...

متن کامل

Determination of Methotrexate in Biological Fluids and a Parenteral Injection Using Terbium-Sensitized Method

A new sensitive, simple and rapid method for determination of methotrexate (MTX) was developed based on quenching effects of MTX on the fluorescence intensity of Tb3+-1,10-phenanthroline complex. The fluorescence intensity was measured with excitation wavelength of 300 nm and emission wavelength of 545 nm and the quenched fluorescence intensity is proportional to the concentration of MTX in Tris...

متن کامل

Determination of ulifloxacin by terbium-sensitized fluorescence with second-order scattering and its applications.

This paper reports the determination of ulifloxacin (UFX) by terbium-sensitized fluorescence using a second-order scattering method. UFX and Tb(III) ion form a fluorescence complex in aqueous solution, and its maximum excitation and emission wavelengths are located at 273 and 545 nm, respectively. In optimum conditions, the relative intensity at 545 nm has a linear relationship to the concentra...

متن کامل

Development of a Simple and Sensitive Terbium Sensitized Fluorescence Method for Determination of Epinephrine and Norepinephrine in Serum

     A simple, rapid, selective and highly sensitive fluorimetric method for determination of two catecholamines, i.e. norepinephrine (NE) and epinephrine (EP), in serum samples was developed. The method is based on the fluorescence sensitization of terbium (Tb3+) by complexation with both catecholamines in the presence of lanthanum (La3+), as a co-cation, and in a Na...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Luminescence : the journal of biological and chemical luminescence

دوره 21 1  شماره 

صفحات  -

تاریخ انتشار 2006