Temporal interactions during paired-electrode stimulation in two retinal prosthesis subjects.
نویسندگان
چکیده
PURPOSE Since 2002, six blind patients have undergone implantation of an epiretinal 4 × 4 electrode array designed to directly stimulate the remaining cells of the retina after severe photoreceptor degeneration due to retinitis pigmentosa. This study was conducted to investigate how the brightness of percepts is affected by pulse timing across electrodes in two of these patients. METHODS Subjects compared the perceived brightness of a standard stimulus (synchronous pulse trains presented across pairs of electrodes) to the perceived brightness of a test stimulus (pulse trains across the electrode pair phase shifted by 0.075, 0.375, 1.8, or 9 ms). The current amplitude necessary for each phase-shifted test stimulus to match the brightness of the standard was determined. RESULTS Depending on the electrode pair, interactions between electrodes were either facilitatory (the perceived brightness produced by stimulating the pair of electrodes was greater than that produced by stimulating either electrode alone) or suppressive (the perceived brightness produced by stimulating the pair of electrodes was less than that produced by stimulating either electrode alone). The amount of interaction between electrodes decreased as a function of increased separation both in time (the phase-shift between pulse trains) and space (center-to-center distance between the electrode pair). CONCLUSIONS For visual prostheses to represent visual scenes that are changing in both space and time requires the development of spatiotemporal models describing the effects of stimulation across multiple electrodes. During multielectrode stimulation, interactions between electrodes have a significant influence on subjective brightness that includes both facilitatory and suppressive effects, and these interactions can be described with a simple computational model. (ClinicalTrials.gov number, NCT00279500.).
منابع مشابه
Flexible Electrode Array for Retinal Stimulation
In this Work, ITO/PET (Indium Tin Oxide / Polyethylene Terephthalate) electrode structure which provides biocompatibility, mechanical stability and flexibility is fabricated. Flexible ITO/PET implantable electrode array for a retina has been developed. The electrode array is fabricated on a thin PET/ITO substrate and is encapsulated using, SU-8, an insulating material. PET substrate and SU-8 po...
متن کاملSpatiotemporal interactions in retinal prosthesis subjects.
PURPOSE Vision loss due to retinitis pigmentosa affects an estimated 15 million people worldwide. Through collaboration between Second Sight Medical Products, Inc., and the Doheny Eye Institute, six blind human subjects underwent implantation with epiretinal 4 x 4 electrode arrays designed to directly stimulate the remaining cells of the retina, with the goal of restoring functional vision by a...
متن کاملThe Perceptual Effects of Chronic Retinal Stimulation
Abstract Can functional vision be restored in blind human subjects using a microelectronic retinal prosthesis? The initial indications suggest that, yes, it is possible. However, the visual experience of these subjects is nothing like a digital scoreboard-like movie, with each electrode acting as an independent pixel. The work described here in this chapter suggests that there are interactions ...
متن کاملA Virtual Electrode through Summation of Time Offset Pulses
Retinal prostheses have been successful in eliciting visual responses in implanted subjects. As these prostheses progress, one of their major limitations is the need for increased resolution. As an alternative to increasing the number of electrodes, virtual electrodes may be used to increase the effective resolution of current electrode arrays. This paper presents a virtual electrode technique ...
متن کاملPredicting visual sensitivity in retinal prosthesis patients.
PURPOSE With the long-term goal of restoring functional vision in patients with retinal degenerative diseases, the eyes of blind human subjects were implanted chronically with epiretinal prostheses consisting of two-dimensional electrode arrays that directly stimulated cells of the neural retina. METHODS Psychophysical techniques were used to measure the brightness of electrically generated p...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Investigative ophthalmology & visual science
دوره 52 1 شماره
صفحات -
تاریخ انتشار 2011