The use of monoclonal antibodies and flow cytometry in the diagnosis of paroxysmal nocturnal hemoglobinuria.

نویسندگان

  • S E Hall
  • W F Rosse
چکیده

We have characterized the erythrocytes, granulocytes, and platelets of 54 patients with paroxysmal nocturnal hemoglobinuria (PNH) with antibodies to glycosylphosphatidylinositol-anchored proteins (anti-CD55, anti-CD59, and anti-CD16) and flow cytometry to establish the usefulness of this technique in the diagnosis of this disorder. All patients demonstrated either completely (PNH III) or partially (PNH II) deficient red cells and granulocytes. Anti-CD59 best demonstrated PNH II red cells, which were present in 50% of the patients. The proportion of abnormal granulocytes was usually greater than the proportion of abnormal red cells; 37% of the patients had >80% abnormal granulocytes. Anti-CD55 did not delineate the erythrocyte populations as well as did anti-CD59. Either anti-CD55 or anti-CD59 could be used equally well to analyze granulocytes; anti-CD16 did not demonstrate cells of partial deficiency. Platelets could not be used for detailed analysis as the normal and abnormal populations were not well distinguished. Flow cytometry of erythrocytes using anti-CD59 or of granulocytes using either anti-CD55 or anti-CD59 provides the most accurate technique for the diagnosis of paroxysmal nocturnal hemoglobinuria; it is clearly more specific, more quantitative, and more sensitive than the tests for PNH that depend upon hemolysis by complement (the acidified serum lysis [Ham] test, the sucrose lysis test, and the complement lysis sensitivity [CLS] test).

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Markedly high population of affected reticulocytes negative for decay-accelerating factor and CD59 in paroxysmal nocturnal hemoglobinuria.

Paroxysmal nocturnal hemoglobinuria (PNH) blood cells lack glycosylphosphatidylinositol-anchored membrane proteins such as decay-accelerating factor (DAF) and CD59. This lack is of diagnostic value in PNH. Because reticulocytes in PNH are not yet well characterized, we analyzed reticulocytes obtained from 12 patients with PNH and from 5 healthy volunteers by two-color flow cytometry with a memb...

متن کامل

Technical advances in flow cytometry-based diagnosis and monitoring of paroxysmal nocturnal hemoglobinuria

Objective: To discuss the implementation of technical advances in laboratory diagnosis and monitoring of paroxysmal nocturnal hemoglobinuria for validation of high-sensitivity flow cytometry protocols. Methods: A retrospective study based on analysis of laboratory data from 745 patient samples submitted to flow cytometry for diagnosis and/or monitoring of paroxysmal nocturnal hemoglobinuria. ...

متن کامل

Paroxysmal nocturnal hemoglobinuria.

Keywords Disease name and synonym Definition and Differential Diagnosis Etiology Clinical Description Diagnostic Methods Epidemiology Management References Abstract Paroxysmal nocturnal hemoglobinuria (PNH) is an acquired clonal disorder of the bone marrow characterized by the lack (total or partial) of all proteins normally attached to the cell membrane by the glycosylphosphatidylinositol (GPI...

متن کامل

Intestinal perforation in a patient with paroxysmal nocturnal hemoglobinuria

Paroxysmal nocturnal hemoglobinuria (PNH) is a rare hematologic disorder that manifests with hemolytic anemia, thrombosis, and peripheral blood cytopenias.Acute abdominal pain is one of the PNH clinical manifestations due to venous thrombosis of intra-abdominal sites including hepatic, portal, mesenteric, and splenic veins.Eculizumaband allogeneic bone marrow transplantation (BMT) arethe only w...

متن کامل

Paroxysmal nocturnal hemoglobinuria clone in 103 Brazilian patients: diagnosis and classification

BACKGROUND Paroxysmal nocturnal hemoglobinuria is an acquired chronic hemolytic anemia, which often manifests as peripheral blood cytopenias and thrombosis. OBJECTIVE The aim of this study is to describe a Brazilian population of paroxysmal nocturnal hemoglobinuria patients. METHODS One hundred and three paroxysmal nocturnal hemoglobinuria cases were retrospectively reviewed and the clinica...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Blood

دوره 87 12  شماره 

صفحات  -

تاریخ انتشار 1996