In vitro fluid dynamics of the Ahmed glaucoma valve modified with expanded polytetrafluoroethylene.
نویسندگان
چکیده
PURPOSE Long-term intraocular pressure reduction by glaucoma drainage devices (GDDs) is often limited by the fibrotic capsule that forms around them. Prior work demonstrates that modifying a GDD with a porous membrane promotes a vascularized and more permeable capsule. This work examines the in vitro fluid dynamics of the Ahmed valve after enclosing the outflow tract with a porous membrane of expanded polytetrafluoroethylene (ePTFE). MATERIALS AND METHODS The control and modified Ahmed implants (termed porous retrofitted implant with modified enclosure or PRIME-Ahmed) were submerged in saline and gelatin and perfused in a system that monitored flow (Q) and pressure (P). Flow rates of 1-50 μl/min were applied and steady state pressure recorded. Resistance was calculated by dividing pressure by flow. RESULTS Modifying the Ahmed valve implant outflow with expanded ePTFE increased pressure and resistance. Pressure at a flow of 2 μl/min was increased in the PRIME-Ahmed (11.6 ± 1.5 mm Hg) relative to the control implant (6.5 ± 1.2 mm Hg). Resistance at a flow of 2 μl/min was increased in the PRIME-Ahmed (5.8 ± 0.8 mm Hg/μl/min) when compared to the control implant (3.2 ± 0.6 mm Hg/μl/min). CONCLUSIONS Modifying the outflow tract of the Ahmed valve with a porous membrane adds resistance that decreases with increasing flow. The Ahmed valve implant behaves as a variable resistor. It is partially open at low pressures and provides reduced resistance at physiologic flow rates.
منابع مشابه
Glaucoma Surgery in Pregnancy: A Case Series and Literature Review
AbstractGlaucoma management in pregnant patients is a real challenge, especially when the glaucoma is not controlled with medications. We report the results of 6 incisional glaucoma surgeries for the management of medically uncontrolled glaucoma patients during pregnancy. This retrospective, case series was conducted on the 6 eyes of 3pregnant patients with uncontrolled glaucoma using maximum t...
متن کاملCreation of a drug-coated glaucoma drainage device using polymer technology: in vitro and in vivo studies.
OBJECTIVE To create and test a slow-release antifibrotic drug-coated glaucoma drainage device using in vitro and in vivo experiments. METHODS A slow-release device incorporating mitomycin C in poly(2-hydroxyethyl methacrylate) disks was developed using redox-polymerization techniques. A standardized preparation of this drug delivery device was attached to the Ahmed glaucoma valve (model FP7; ...
متن کاملHomemade expanded-polytetrafluoroethylene flexible mitral annuloplasty ring.
A homemade mitral annular prosthesis has been developed using expanded-polytetrafluoroethylene material. It is safe in that it avoids the risk of prosthesis wrinkle when stitches are tied. Simultaneously, it is strong enough to prevent future stretching and rupture. This device has been implanted in 60 patients with good and stable results at 42 months of follow-up. Our flexible mitral annular ...
متن کاملUsing Ahmed’s Gonioimplant Valve to Surgical Treatment of Glaucoma in Two Dogs
Case Description- An eleven-year-old Golden retriever male dog (dog I) and a four-year-old neutered Toy Terrier (dog II) were referred to Small Animal Clinic. Dog I was suffered from partial loss of vision and engorgement of episcleral vessels of his right eye and dog II was blind. Intraocular pressure (IOP) of right eye was 37.8 mmHg in dog I and 34.5 and 31.6 mmHg in the right and left...
متن کاملMR imaging features of giant reservoir formation in the orbit: an unusual complication of Ahmed glaucoma valve implantation.
We report the MR imaging findings of an unusually large fluid collection, so-called giant reservoir, around an Ahmed glaucoma valve implant that caused progressive proptosis in a patient with posttraumatic glaucoma. Although other cystic lesions of the juxtalacrimal area of the orbit, such as dermoid cyst, can present similar imaging findings, the characteristic morphology and location should l...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Current eye research
دوره 36 2 شماره
صفحات -
تاریخ انتشار 2011