Success rate of transcranial color-coded duplex ultrasonography in visualizing the basal cerebral arteries in vascular patients over 60 years of age.
نویسندگان
چکیده
BACKGROUND AND PURPOSE Clinically important atherosclerotic cerebrovascular disease is mainly found in patients aged >60 years. Transcranial color-coded duplex ultrasonography (TCCD) is a relatively new technique for investigating the basal cerebral arteries; however, it is often hampered by impenetrable ultrasound windows. The aim of this study was to ascertain the as yet unknown success rate of TCCD regarding visualization of the basal cerebral arteries in patients >60 years, to provide reference data, and to compare any possible male/female differences. METHODS In 112 atherosclerotic white patients >60 years of age, the anterior, middle, and posterior cerebral arteries and the vertebral and basilar arteries were insonated. RESULTS In men, 99% of the temporal and 94% of the suboccipital windows could be penetrated by ultrasound compared with 77% and 95%, respectively, in women. The male versus female vessel detection rates were 91% versus 58% for the anterior cerebral artery, 97% versus 73% for the middle cerebral artery, 97% versus 68% for the posterior cerebral artery, 94% versus 93% for the vertebral artery, and 91% versus 79% for the basilar artery. In 77% of men but only 33% of women could all vascular segments be investigated. All intracranial arteries were insonated at a deeper level in men. The women showed significantly higher blood flow velocities than the men. CONCLUSIONS In elderly white men the vessel detection rate is >90%. In women there is a much lower detection rate, due to impenetrable temporal windows. Visualization of all major intracranial arteries is possible in only one third of female patients >60 years of age.
منابع مشابه
Assessment of >/=50% and <50% intracranial stenoses by transcranial color-coded duplex sonography.
BACKGROUND AND PURPOSE A favorable risk-benefit ratio for warfarin compared with aspirin has been reported for the prevention of major vascular events in symptomatic >/=50% intracranial stenoses. Transcranial color-coded duplex sonography (TCCS) criteria providing an accurate detection of >/=50% and <50% stenoses of the anterior, middle, and posterior cerebral arteries and basilar and vertebral...
متن کاملTranscranial Color-Coded Sonography of the Basal Cerebral Circulation
Background and Purpose Transcranial color-coded sonography is a new development in noninvasive cerebral vascular imaging. Reference data using this technique are described. Methods Blood velocities and pulsatility and resistance indices were determined in the anterior cerebral, middle cerebral, posterior cerebral, vertebral, and basilar arteries in 115 volunteers after correction for the angle ...
متن کاملTranscranial color-coded sonography of the basal cerebral circulation. Reference data from 115 volunteers.
BACKGROUND AND PURPOSE Transcranial color-coded sonography is a new development in noninvasive cerebral vascular imaging. Reference data using this technique are described. METHODS Blood velocities and pulsatility and resistance indices were determined in the anterior cerebral, middle cerebral, posterior cerebral, vertebral, and basilar arteries in 115 volunteers after correction for the angl...
متن کاملTranscranial color-coded duplex sonography in unilateral flow-restrictive extracranial carotid artery disease.
PURPOSE To provide transcranial color-coded duplex flow-velocity data for the basal cerebral arteries in patients with unilateral flow-restrictive extracranial carotid artery disease, and to compare these data with the flow velocities obtained in healthy control subjects. METHODS Transcranial color-coded duplex sonography was performed in 78 patients with different patterns of cross flow thro...
متن کاملVertebrobasilar transcranial color-coded duplex ultrasonography: improvement with echo enhancement.
BACKGROUND AND PURPOSE The diagnostic yield of vertebrobasilar transcranial color-coded duplex ultrasonography (US) is often hampered by insufficient acoustic penetration, anatomic variations, and vessel tortousity. The purpose of this study was to evaluate the effect of echo enhancement on vertebrobasilar transcranial color-coded duplex US. METHODS In 23 consecutive patients (mean age, 61.0 ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Stroke
دوره 30 7 شماره
صفحات -
تاریخ انتشار 1999