Quantitative antimicrobial susceptibility testing of Haemophilus influenzae and Streptococcus pneumoniae by using the E-test.

نویسندگان

  • J H Jorgensen
  • A W Howell
  • L A Maher
چکیده

The E-test (PDM Epsilometer; AB Biodisk, Solna, Sweden) is an antimicrobial agent gradient-coated plastic test strip which allows MIC determinations on agar media. The test is performed in a manner similar to the agar disk diffusion procedure. A collection of Haemophilus influenzae and Streptococcus pneumoniae strains possessing various resistance mechanisms was used to evaluate the E-test method. H. influenzae strains were tested with both Haemophilus test medium (HTM) and PDM ASM II chocolate agar, while the S. pneumoniae strains were tested on Mueller-Hinton sheep blood agar. E-test MICs for a total of 10 antimicrobial agents were compared with broth microdilution MICs determined according to National Committee for Clinical Laboratory Standards methods. In general, E-test MICs for both species were quickly and easily interpreted and agreed within one log2 MIC increment in 89.8% of tests with H. influenzae and in 80.4% of pneumococcal tests. The majority of disagreements between the E-test and conventional MICs occurred with trimethoprim-sulfamethoxazole because of trailing and diffuse E-test MIC endpoints with both species. Ampicillin MICs for beta-lactamase-producing H. influenzae determined by the E-test differed at times from those determined by conventional testing because of the vagaries of interpreting colonies growing within the E-test inhibition ellipses. E-test penicillin MICs for pneumococci tended to be 1 to 2 log2 dilutions lower than those determined by using Mueller-Hinton broth supplemented with lysed horse blood. Nevertheless, strains of both species with documented resistance to the study drugs were detected by E-tests, i.e., 0.7% of the tests had very major errors with H. influenzae and 0.8% had very major errors with S. pneumoniae. Thus, the E-test represents a potential alternative method for antimicrobial susceptibility testing of these two fastidious bacterial species.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Performance Evaluation of a Newly Developed and Fully Automated Bacteriological Analyzer "RAISUS ANY" for Antimicrobial Susceptibility Testing of Fastidious Bacteria Haemophilus influenzae and Streptococcus pneumoniae.

OBJECTIVE Antimicrobial susceptibility testing for fastidious bacteria, such as Haemophilus influenzae (H. influenzae) and Streptococcus pneumoniae (S. pneumoniae) has been performed manually. We evaluated the performance of a newly developed fully automated system for rapid bacterial identification and antimicrobial susceptibility testing "RAISUS ANY" (Nissui Pharmaceutical Co., Ltd.). METHO...

متن کامل

Potentially Preventable Number of Cases and Deaths Associated with Pneumococcal Diseases and Haemophilus Influenzae in Iran during (2010-2013)

Background: Streptococcus pneumoniae and Haemophilus influenzae type b (Hib) is a leading cause of bacterial pneumonia, meningitis, and sepsis in children under 5-year of age. This study aims to estimate potentially preventable number of cases and deaths caused by Hib and pneumococcal in Iran.Materials and Methods:We used the burden of diseases model estimates of the World Health Organization (...

متن کامل

Use of Haemophilus test medium for broth microdilution antimicrobial susceptibility testing of Streptococcus pneumoniae.

A recently described medium (Haemophilus test medium [HTM]) for antimicrobial susceptibility testing of Haemophilus influenzae was evaluated in this study for broth microdilution testing of Streptococcus pneumoniae. A total of 137 clinical isolates was tested against 11 antimicrobial agents, using Mueller-Hinton broth supplemented with 3% lysed horse blood in parallel with HTM. Inocula of 5 X 1...

متن کامل

Comparative in vitro activity of telithromycin against macrolide-resistant and -susceptible Streptococcus pneumoniae, Moraxella catarrhalis and Haemophilus influenzae.

OBJECTIVES The first objective was to investigate the in vitro activity of telithromycin against respiratory tract pathogens in comparison with other antimicrobial agents. The second objective was to identify the influence of the erm(B) and mef(A) genes on the susceptibility of Streptococcus pneumoniae to telithromycin. METHODS The in vitro activity of telithromycin against S. pneumoniae, Mor...

متن کامل

Impact of carbon dioxide on the susceptibility of key respiratory tract pathogens to telithromycin and azithromycin.

OBJECTIVES To determine the quantitative differences in telithromycin and azithromycin MIC values against Streptococcus pneumoniae, Haemophilus influenzae and Streptococcus pyogenes obtained using two recommended and commonly used methodologies: CLSI reference standard broth microdilution in ambient air and Etest((R)) concentration gradient in CO(2). METHODS Four hundred clinical isolates (S....

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of clinical microbiology

دوره 29 1  شماره 

صفحات  -

تاریخ انتشار 1991