Can Posterior Lumbar Instrumentation and Fusion Be Overpowered by Anterior Lumbar Fusion With Hyperlordotic Cages? A Cadaveric Study
نویسندگان
چکیده
STUDY DESIGN Technical report on cadavers. OBJECTIVE To evaluate preliminary feasibility and safety of lumbar sagittal alignment correction with anterior hyperlordotic cages used to overpower previous posterior spinal instrumentation. METHODS Hyperlordotic 30° anterior lumbar interbody fusion (ALIF) cages were inserted in collapsed L5-S1 disc space of 2 cadavers to overpower prior posterior L5-S1 pedicle screws and rod constructs. A distinct technique of opening up the disc space and creation of intersegmental lordosis was employed using a large endplate distractor and transforaminal lumbar interbody fusion (TLIF) paddle distractor. Assessment of increase in the intersegmental lordosis (ISL) was made using lateral fluoroscopic imaging. Postprocedural computed tomography (CT) scans were obtained to evaluate any failure of posterior instrumentation and to serve as a surrogate marker for bone quality. RESULTS The 2 cadavers selected (from an available number of 10) were males: 82 and 84 years of age, respectively. Both had marked L5-S1 disc space collapse. The ISL achieved with hyperlordotic cages was 27.6° for the first cadaver (up from 4.9°) and 23.1° for the second one (up from 4.6°). No obvious screw-rod failure or cutout of instrumentation occurred. Postprocedure CT scans did not reveal any loosening of screws or cutout through endplates. Hounsfield unit values calculated on axial CT cuts were 73.50 (osteoporosis) and 80.70 (osteopenia) respectively for the 2 cadavers. CONCLUSION Based on the results of the cadaveric experiment, overpowering of posterior instrumentation can be effectively achieved. Biomechanical and clinical studies are indicated to further evaluate the suitability and safety of this technique.
منابع مشابه
بررسی عوارض جراحی پولیواسکولیوز
This is a retrospective study of 83 patients with polioscoliosis, treated surgically in Shafa hospital (1970-1997), and the results are as Follow: implant failure: 15 cases (18%), pseudoar throsis: 12 cases (14.5%) deep infection: 4 cases (4.5%) superficial infection: 3 cases (3.6%) cast sore: 17 cases (20.5%) and loss of correction: 28 cases (33.7%). Implant failure was more common in Harr...
متن کاملLumbar lordosis restoration following single-level instrumented fusion comparing 4 commonly used techniques.
A major sequelae of lumbar fusion is acceleration of adjacent-level degeneration due to decreased lumbar lordosis. We evaluated the effectiveness of 4 common fusion techniques in restoring lordosis: instrumented posterolateral fusion, translumbar interbody fusion, anteroposterior fusion with posterior instrumentation, and anterior interbody fusion with lordotic threaded (LT) cages (Medtronic So...
متن کاملStability After Anterior Lumbar Fusion with Interbody Cages: A Radiostereometric Evaluation
Background: Interbody cage stabilization as a stand-alone procedure in lumbar spine fusion is questioned due to inconsistent mechanical effects registered in human cadaveric studies. Even segmental mobility exceeding the normal range of motion is described after cage implantation. For the anterior interbody cage fusion, this potential, undesired destabilization is explained by the resection of ...
متن کاملComparison of Supplementary Posterior Fixations for Two-Level ALIF with Stand-Alone Cages
INTRODUCTION: Structural cages have been widely used in recent years to maintain motion segment height and stability in anterior lumbar interbody fusion (ALIF). High rate of clinical success and radiological fusion rate have been reported following single-level fusion using these cages. However, many biomechanical studies report insufficient stability, especially with extension loading. Posteri...
متن کاملTraumatic Lumbosacral Dislocation Treated with Posterior Lumbar Interbody Fusion Using Intersomatic Cages
A 35-year-old man was struck by a car on his right side and presented with paraparesis of both lower extremities. Radiographic examination revealed multiple transverse process fractures and anterior displacement of L5 on S1. Computed tomography revealed a bilateral anterior facet dislocation of the fifth lumbar vertebra on the sacrum. MRI showed rupture of the posterior ligamentous complex. A p...
متن کامل