Fabry-Perot interferometer embedded in a glass chip fabricated by femtosecond laser.

نویسندگان

  • Cheng-Hsiang Lin
  • Lan Jiang
  • Hai Xiao
  • Yen-Hsin Chai
  • Shean-Jen Chen
  • Hai-Lung Tsai
چکیده

We report a simple Fabry-Perot interferometer (FPI) embedded in a glass chip, which is capable of precisely measuring the refractive indices of liquid samples. The microdevice is the integration of a single-mode optical fiber and a microchannel in the photosensitive glass fabricated by femtosecond laser followed by thermal treatment, wet etching, and annealing. The function of the FPI is demonstrated by measuring the refractive indices of water and methanol. The interference visibility is more than 4.0 dB, which is sufficient for most sensing applications. This refractive index sensor with rigid structure could be further integrated to become a more complex 3D lab-on-a-chip for reliable biomedical applications.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Miniaturized fiber inline Fabry-Perot interferometer fabricated with a femtosecond laser.

We report a miniaturized inline Fabry-Perot interferometer directly fabricated on a single-mode optical fiber with a femtosecond laser. The device had a loss of 16 dB and an interference visibility exceeding 14 dB. The device was tested and survived in high temperatures up to 1100 degrees C. With an accessible cavity and all-glass structure, the new device is attractive for sensing applications...

متن کامل

Optical fiber Fabry-Perot interferometer cavity fabricated by femtosecond laser micromachining and fusion splicing for refractive index sensing.

We demonstrate a fiber in-line Fabry-Perot interferometer cavity sensor for refractive index measurement. The interferometer cavity is formed by drilling a micro-hole at the cleaved fiber end facet, followed by fusion splicing. A micro-channel is inscribed by femtosecond laser micromachining to vertically cross the cavity to allow liquid to flow in. The refractive index sensitivity obtained is ...

متن کامل

The Comparison of Environmental Effects on Michelson and Fabry-Perot Interferometers Utilized for the Displacement Measurement

The optical structure of general commercial interferometers, e.g., the Michelson interferometers, is based on a non-common optical path. Such interferometers suffer from environmental effects because of the different phase changes induced in different optical paths and consequently the measurement precision will be significantly influenced by tiny variations of the environmental conditions. Fab...

متن کامل

A novel algorithm for the signal interpolation of the displacement measurement based on a Fabry-Perot interferometer

Current commercial interferometers reveal excellent measurement performances, because of its major advantage which enables the displacement measurement with the characterization of the high resolution under the large measuring range. FabryPerot interferometer is a compact interferometer with the structure of common optical path. In comparison with the ordinary commercial laser interferometers h...

متن کامل

Chitosan Layer Fabry - Perot Interferometer - Based Optical Fiber Sensor for Cadmium Ion Detection

Optical sensors based on Fabry-Perot interferometer to detect cadmium ions is proposed. The sensor was fabricated by coating the tip of the optical fiber by chitosan. The two chitosan surfaces serve as mirrors which form a Fabry-Perot interferometer. The characterization results indicate that the sensor has a linear response with sensitivity of 0.0884 dBm/ppm with a correlation factor of 0.9665...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Optics letters

دوره 34 16  شماره 

صفحات  -

تاریخ انتشار 2009