Reduced oxygen content in equilibrated fresh heparinized and ACD-stored blood from cigarette smokers.
نویسندگان
چکیده
We have shown recently, in fresh heparinized blood drawn from smokers and equilibrated with 95 per cent oxygen in vitro for periods exceeding 30 min, that the oxygen content determined by Van Slyke analysis is significantly lower than in non-smokers' blood. The findings, which we have noted briefly elsewhere (Gregory, Hulands and Millar, 1972), were obtained during investigation of the normal oxygen combining capacity of human haemoglobin, and are similar to those reported by Bureaux and associates (1971). We have, therefore, sought similar effects in blood donated by heavy smokers and stored in the usual way in ACD solutions.
منابع مشابه
The behavior, as regards shape and volume, of human red cell ghosts in fresh and in stored blood.
By ERIC 1 ONDER AND DELIA BARRETO T HIS PAPER is concermied with the way imi which the volumue and shape of human red cell ghosts, two properties relate to the structure of the ghost and probably related to the structure of the red cells from which they are derived, behave as the red cells fromn which the ghosts are prepared are stored for increasimig periods of time at 4 C. The problem will be...
متن کاملPostoperative Hypoxemia and Oxygen Need in Bakers Compared with Cigarette and Water Pipe Smokers
Background: Hypoxemia is a frequent complication after general anesthesia. It usually takes longer to recover in individuals with respiratory problems. Bakers may suffer from respiratory problems such as asthma. The objective of this study was to compare the occurrence of hypoxemia and duration of supplemental oxygen administration during recovery from general anesthesia in bakers and smokers. ...
متن کاملOxygen delivery following transfusion of stored blood. I. Normal rats.
RINGLE, AND STANLEY I?. BALCERZAK. Oxygen delivery following transfusion of stored blood. I. Normal rats. J. Appl. Physiol. 37(l) : 60-63. 1974 .-Blood stored in acid-citrate-dextrose (ACD) develops increased oxygen affinity secondary to progressive decline of red cell 2,3-diphosphoglycerate (DPG) levels. The ability of stored blood to supply oxygen to tissues was studied in rats exchange-trans...
متن کاملBlood oxygen capacity. Technical difficulties of its determination by the Van Slyke method and comparison with hemoglobin content.
During determination of the oxygen capacity of blood by the Van Slyke method (1), the following adaptations were made in order to reduce errors: (1) Blood was equilibrated with water-saturated air in a siliconized tonometer. (2) The determination of the oxygen content of the sample was carried out immediately after equilibration. (3) Triton was used instead of saponin in the ferricyanide reagen...
متن کاملS21-26_swu 4.pmd
The lymphocyte proliferation assay (LPA) is a technique to determine T-lymphocyte functions in vitro. The standard LPA using peripheral blood mononuclear cells (PBMC) separated from heparinized blood requires a large blood sample, time consuming and expensive. It is more useful if acid citrate dextrose (ACD) blood could be used not only for LPA but also for other purposes. To determine whether ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- British journal of anaesthesia
دوره 44 10 شماره
صفحات -
تاریخ انتشار 1972