Sensitivity and Specificity of a Urine Circulating Anodic Antigen Test for the Diagnosis of Schistosoma haematobium in Low Endemic Settings

نویسندگان

  • Stefanie Knopp
  • Paul L. A. M. Corstjens
  • Artemis Koukounari
  • Colin I. Cercamondi
  • Shaali M. Ame
  • Said M. Ali
  • Claudia J. de Dood
  • Khalfan A. Mohammed
  • Jürg Utzinger
  • David Rollinson
  • Govert J. van Dam
چکیده

BACKGROUND Elimination of schistosomiasis as a public health problem and interruption of transmission in selected areas are key goals of the World Health Organization for 2025. Conventional parasitological methods are insensitive for the detection of light-intensity infections. Techniques with high sensitivity and specificity are required for an accurate diagnosis in low-transmission settings and verification of elimination. We determined the accuracy of a urine-based up-converting phosphor-lateral flow circulating anodic antigen (UCP-LF CAA) assay for Schistosoma haematobium diagnosis in low-prevalence settings in Zanzibar, Tanzania. METHODOLOGY A total of 1,740 urine samples were collected in 2013 from children on Pemba Island, from schools where the S. haematobium prevalence was <2%, 2-5%, and 5-10%, based on a single urine filtration. On the day of collection, all samples were tested for microhematuria with reagent strips and for the presence of S. haematobium eggs with microscopy. Eight months later, 1.5 ml of urine from each of 1,200 samples stored at -20°C were analyzed by UCP-LF CAA assay, while urine filtration slides were subjected to quality control (QCUF). In the absence of a true 'gold' standard, the diagnostic performance was calculated using latent class analyses (LCA). PRINCIPAL FINDINGS The 'empirical' S. haematobium prevalence revealed by UCP-LF CAA, QCUF, and reagent strips was 14%, 5%, and 4%, respectively. LCA revealed a sensitivity of the UCP-LF CAA, QCUF, and reagent strips of 97% (95% confidence interval (CI): 91-100%), 86% (95% CI: 72-99%), and 67% (95% CI: 52-81%), respectively. Test specificities were consistently above 90%. CONCLUSIONS/SIGNIFICANCE The UCP-LF CAA assay shows high sensitivity for the diagnosis of S. haematobium in low-endemicity settings. Empirically, it detects a considerably higher number of infections than microscopy. Hence, the UCP-LF CAA employed in combination with QCUF, is a promising tool for monitoring and surveillance of urogenital schistosomiasis in low-transmission settings targeted for elimination.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Accuracy of Urine Circulating Cathodic Antigen (CCA) Test for Schistosoma mansoni Diagnosis in Different Settings of Côte d'Ivoire

BACKGROUND Promising results have been reported for a urine circulating cathodic antigen (CCA) test for the diagnosis of Schistosoma mansoni. We assessed the accuracy of a commercially available CCA cassette test (designated CCA-A) and an experimental formulation (CCA-B) for S. mansoni diagnosis. METHODOLOGY We conducted a cross-sectional survey in three settings of Côte d'Ivoire: settings A ...

متن کامل

Application of immunodiagnostic assays: detection of antibodies and circulating antigens in human schistosomiasis and correlation with clinical findings.

In an initial cross-sectional survey, serum, urine, and stool samples were collected from 370 participants representing about 10% of the population (n = 4,438) in Behbeet village, 50 km south of Cairo, Egypt, an area well known to be endemic solely for Schistosoma haematobium. Diagnosis was approached in two parallel ways. The first approach, which simulated actual conditions in many endemic ar...

متن کامل

Circulating anodic and cathodic antigen in serum and urine of mixed Schistosoma haematobium and S. mansoni infections in Office du Niger, Mali.

In Office du Niger, an area endemic for both Schistosoma haematobium and S. mansoni in Mali, circulating anodic (CAA) and cathodic (CCA) antigen detection assays were performed on pretreatment serum and urine samples from two villages, Rigandé and Siguivoucé, and compared with egg counting methods. The highest prevalence was obtained with the urine-CCA assay which also had the highest sensitivi...

متن کامل

Accuracy of circulating cathodic antigen tests for rapid mapping of Schistosoma mansoni and S. haematobium infections in Southern Sudan.

OBJECTIVE To evaluate the diagnostic accuracy of a circulating cathodic antigen (CCA) urine dipstick test for detecting Schistosoma mansoni and S. haematobium alongside an integrated rapid mapping survey in Southern Sudan. METHODS AND RESULTS A total of 373 children aged 5-16 years were included in the study. Of these 26.0% were infected with S. haematobium and 24.5% were infected with S. man...

متن کامل

Circulating antigen tests and urine reagent strips for diagnosis of active schistosomiasis in endemic areas

BACKGROUND Point-of-care (POC) tests for diagnosing schistosomiasis include tests based on circulating antigen detection and urine reagent strip tests. If they had sufficient diagnostic accuracy they could replace conventional microscopy as they provide a quicker answer and are easier to use. OBJECTIVES To summarise the diagnostic accuracy of: a) urine reagent strip tests in detecting active ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 9  شماره 

صفحات  -

تاریخ انتشار 2015