Clinical implementation of MR‐guided vaginal cylinder brachytherapy
نویسندگان
چکیده
We present an institutional experience on the clinical implementation of magnetic resonance (MR)-guided vaginal brachytherapy using commercially available solid applicator models. To test the fidelity of solid applicator models to digitize vaginal cylinder applicators, three datasets were evaluated. The first included 15 patients who were simulated with CT alone. Next, a water phantom was used to evaluate vaginal cylinders ranging from 20 to 35 mm in diameter with CT and MR. Finally, three patients undergoing HDR brachytherapy with vaginal cylinders that were simulated with both CT and MR were evaluated. In these assessments, the solid applicator models were aligned based on the outline of the applicators on the corresponding volumetric image, and deviations between the central source positions defined based on X-ray markers (on CT) and solid applicator models (on CT and MR), and the percent dose difference between select reference points were calculated. The mean central source deviation defined based on X-ray markers (on CT) and solid applicator models (on CT and MR) for the 15-patient cohort, the phantom, and the 3-patient cohort is 0.6 mm, 0.6 mm, and 1.2 mm, respectively. The average absolute percent dose difference for the bladder, rectum, prescription, and inferior reference points were 2.2%, 2.3%, 2.2%, and 2.4%, respectively, for the 15 patient cohort. For the phantom study, the average, absolute percent dose difference for the prescription and inferior reference points are 2.0% and 2.1% for the CT, 2.3% and 2.2% for the T1W, and 2.8% and 3.0% for the T2W images. For the three patient cohort, the average absolute percent dose difference for the bladder, rectum, prescription, and inferior reference points are 2.9%, 2.6%, 3.0%, and 4.2% for the CT, 6.5%, 1.6%, 2.5%, and 4.7% for the T1W, and 6.0%, 7.4%, 2.6, and 2.0% for the T2W images. Based on the current study, aligning the applicator model to MR images provides a practical, efficient approach to perform MR-based brachytherapy planning.
منابع مشابه
Assessment of air pockets in high-dose-rate vaginal cuff brachytherapy using cylindrical applicators
PURPOSE To retrospectively assess the incidence and magnitude of air pockets around vaginal cylinders and its impact on dose distribution in vaginal cuff image-guided high-dose-rate (HDR) brachytherapy. MATERIAL AND METHODS Fifty endometrial carcinoma patients treated by postoperative HDR vaginal cuff brachytherapy were included in the study. The average age of patients was 58.3 ± 11.8 years ...
متن کاملClinical applications of custom-made vaginal cylinders constructed using three-dimensional printing technology
PURPOSE Three-dimensional (3D) printing technology allows physicians to rapidly create customized devices for patients. We report our initial clinical experience using this technology to create custom applicators for vaginal brachytherapy. MATERIAL AND METHODS Three brachytherapy patients with unique clinical needs were identified as likely to benefit from a customized vaginal applicator. Pat...
متن کاملDosimetric Studies in Image-Guided Adaptive Brachytherapy in Gynecological Cancers: A Journey to Successful Implementation
Implementation of Image-guided adaptive brachytherapy (IGABT) in India and other developing countries is a major challenge due to the resources, expertise and financial constraints. The basis of this thesis was to address various issues related to transition and successful implementation of IGABT in clinical routine.[1] Tata Memorial Hospital (TMH), Mumbai has a long tradition of being active i...
متن کاملLocal tumor control probability to evaluate an applicator‐guided volumetric‐modulated arc therapy solution as alternative of 3D brachytherapy for the treatment of the vaginal vault in patients affected by gynecological cancer
The purpose of this study was to evaluate the applicator-guided volumetric-modulated arc therapy (AGVMAT) solution as an alternative to high-dose-rate brachytherapy (HDR-BRT) treatment of the vaginal vault in patients with gynecological cancer (GC). AGVMAT plans for 51 women were developed. The volumetric scans used for plans were obtained with an implanted CT-compatible vaginal cylinder which ...
متن کاملModified Fletcher's 3-channel brachytherapy system with vaginal line source loading versus uterine tandem and vaginal cylinder system in Stage IIIA cervical cancer
PURPOSE The uterine tandem with open-ended vaginal cylinder is the most commonly used brachytherapy system for Federation Internationale de Gynecologie et d'Obstetrique (FIGO) Stage IIIA cervix cancer at the National Cancer Centre, Singapore. Without the 3-channel ovoid system, the dose to the parametrium is often compromised. In this study, a vaginal cylinder that could potentially be incorpor...
متن کامل