An LC/MS/MS method for stable isotope dilution studies of β-carotene bioavailability, bioconversion, and vitamin A status in humans.

نویسندگان

  • Anthony Oxley
  • Philip Berry
  • Gordon A Taylor
  • Joseph Cowell
  • Michael J Hall
  • John Hesketh
  • Georg Lietz
  • Alan V Boddy
چکیده

Isotope dilution is currently the most accurate technique in humans to determine vitamin A status and bioavailability/bioconversion of provitamin A carotenoids such as β-carotene. However, limits of MS detection, coupled with extensive isolation procedures, have hindered investigations of physiologically-relevant doses of stable isotopes in large intervention trials. Here, a sensitive liquid chromatography-tandem mass spectrometry (LC/MS/MS) analytical method was developed to study the plasma response from coadministered oral doses of 2 mg [(13)C10]β-carotene and 1 mg [(13)C10]retinyl acetate in human subjects over a 2 week period. A reverse phase C18 column and binary mobile phase solvent system separated β-carotene, retinol, retinyl acetate, retinyl linoleate, retinyl palmitate/retinyl oleate, and retinyl stearate within a 7 min run time. Selected reaction monitoring of analytes was performed under atmospheric pressure chemical ionization in positive mode at m/z 537→321 and m/z 269→93 for respective [(12)C]β-carotene and [(12)C] retinoids; m/z 547→330 and m/z 274→98 for [(13)C10]β-carotene and [(13)C5] cleavage products; and m/z 279→100 for metabolites of [(13)C10]retinyl acetate. A single one-phase solvent extraction, with no saponification or purification steps, left retinyl esters intact for determination of intestinally-derived retinol in chylomicrons versus retinol from the liver bound to retinol binding protein. Coadministration of [(13)C10]retinyl acetate with [(13)C10]β-carotene not only acts as a reference dose for inter-individual variations in absorption and chylomicron clearance rates, but also allows for simultaneous determination of an individual's vitamin A status.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Bioconversion of dietary provitamin A carotenoids to vitamin A in humans.

Recent progress in the measurement of the bioconversion of dietary provitamin A carotenoids to vitamin A is reviewed in this article. Methods to assess the bioavailability and bioconversion of provitamin A carotenoids have advanced significantly in the past 10 y, specifically through the use of stable isotope methodology, which includes the use of labeled plant foods. The effects of the food ma...

متن کامل

Chemical Synthesis of Deoxynivalenol-3-β-d-[(13)C₆]-glucoside and Application in Stable Isotope Dilution Assays.

Modified mycotoxins have been gaining importance in recent years and present a certain challenge in LC-MS/MS analysis. Due to the previous lack of a labeled isotopologue of the modified mycotoxin deoxynivalenol-3-glucoside, in our study we synthesized the first (13)C-labeled internal standard. Therefore, we used the Königs-Knorr method to synthesize deoxynivalenol-3-β-d-[(13)C₆]-glucoside origi...

متن کامل

The effect of food preparation on the bioavailability of carotenoids from carrots using intrinsic labelling.

A strategy to reduce the incidence of vitamin A deficiency is to improve precursor bioavailability from meals. Since vitamin A precursors are fat-soluble, we noted that carotenoids are more easily absorbed from food if prepared in such a way that the food matrix containing provitamin A (β-carotene) is sufficiently fat rich. To quantify this effect, we have developed a stable isotope methodology...

متن کامل

Stable isotope dilution techniques for assessing vitamin A status and bioefficacy of provitamin A carotenoids in humans.

Vitamin A deficiency is a major global public health problem. Among the variety of techniques that are available for assessing human vitamin A status, evaluating the provitamin A nutritional values of foodstuffs and estimating human vitamin A requirements, isotope dilution provides the most accurate estimates. Although the relative expense of isotope dilution restricts its applications, it has ...

متن کامل

Liquid chromatography with isotope-dilution mass spectrometry for determination of water-soluble vitamins in foods.

Vitamins are essential for improving and maintaining human health, and the main source of vitamins is the diet. Measurement of the quantities of water-soluble vitamins in common food materials is important to understand the impact of vitamin intake on human health, and also to provide necessary information for regulators to determine adequate intakes. Liquid chromatography (LC) and mass spectro...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of lipid research

دوره 55 2  شماره 

صفحات  -

تاریخ انتشار 2014