Selection and optimisation of biventricular pacing: the role of echocardiography.

نویسندگان

  • R E Lane
  • A W C Chow
  • D Chin
  • J Mayet
چکیده

The quantification of ventricular dyssynchrony is a key factor in identifying patients with severe heart failure who may benefit from cardiac resynchronisation with biventricular pacing (BVP). Echocardiographic techniques appear to offer superior sensitivity and specificity than the ECG in selecting these patients. This paper reviews the scope of current echocardiographic techniques for guiding both patient selection and optimisation of device programming following implantation.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The role of speckle tracking strain imaging in cardiac pacing.

In recent years, concerns have been raised about possible harmful effects of long-term right ventricular (RV) apical pacing. These detrimental effects may be related to changes in left ventricular (LV) mechanics during RV apical pacing. As a consequence, alternative RV pacing sites have been proposed, and in selected patients an upgrade from RV to biventricular pacing may be considered. Novel t...

متن کامل

Disappearing left atrial mass with drainage of pericardial effusion.

Trial. Circulation 2008;117:2608–2616. 14. Beshai JF, Grimm RA, Nagueh SF, Baker JH 2nd, Beau SL, Greenberg SM, Pires LA, Tchou PJ, RethinQ Study Investigators. Cardiac-resynchronization therapy in heart failure with narrow QRS complexes. N Engl J Med 2007;357:2461–2471. 15. Lafitte S, Bordachar P, Lafitte M, Garrigue S, Reuter S MD, Reantm P, Serri K, Lebouffos V, Berrhouet M, Jais P, Haissagu...

متن کامل

Mechanical resynchronisation in biventricular pacing illustrated by real time transthoracic three dimensional echocardiography.

A 74 year old man with dilated cardiomyopathy and right bundle branch block underwent implantation of a biventricular pacemaker for treatment of severe heart failure. When reviewed six weeks later his New York Heart Association functional class had improved from III to I. Using the Sonos 7500 Live 3D system, a real time transthoracic three dimensional echocardiogram was performed in the presenc...

متن کامل

Tissue Doppler echocardiography and biventricular pacing in heart failure: Patient selection, procedural guidance, follow-up, quantification of success

Asynchronous myocardial contraction in heart failure is associated with poor prognosis. Resynchronization can be achieved by biventricular pacing (BVP), which leads to clinical improvement and reverse remodeling. However, there is a substantial subset of patients with wide QRS complexes in the electrocardiogram that does not improve despite BVP. QRS width does not predict benefit of BVP and onl...

متن کامل

Three dimensional echocardiography documents haemodynamic improvement by biventricular pacing in patients with severe heart failure.

OBJECTIVES To quantify the short term haemodynamic effects of biventricular pacing in patients with heart failure and left bundle branch block by using three dimensional echocardiography. DESIGN Three dimensional echocardiography was performed in 15 consecutive heart failure patients (New York Heart Association functional class III or IV) with an implanted biventricular pacing system. Six min...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Heart

دوره 90 Suppl 6  شماره 

صفحات  -

تاریخ انتشار 2004