Effect of isthmus anatomy and ablation catheter on radiofrequency catheter ablation of the cavotricuspid isthmus.
نویسندگان
چکیده
BACKGROUND Cavotricuspid isthmus (CTI) characteristics are rarely documented when comparing catheters in radiofrequency ablation (RFA) of atrial flutter (AFL). Our objectives were (1) to evaluate the impact of CTI morphology and length on ablation procedures and (2) to compare the efficacy of an 8-mm-tip catheter with an irrigated cooled-tip RFA in the subgroup presumed to be more difficult to treat (with a long CTI, >35 mm). METHODS AND RESULTS Over a period of 17 months, 185 patients accepted the protocol and underwent an isthmogram in preparation for RFA. Groups were classified according to CTI length and CTI morphology. RFA was performed with an 8-mm-tip catheter for patients with a short CTI, < or =35 mm (n=123), whereas randomization between an 8-mm-tip and a cooled-tip catheter applied to patients with a longer CTI, >35 mm (n=62). For long CTI, 32 patients were assigned to an 8-mm catheter and 30 patients to the cooled-tip RFA ablation group. In this subset, RF application (18.2+/-17 versus 19+/-13 minutes) and x-ray exposure (20.8+/-18 versus 18+/-13 minutes) did not differ between the 8-mm-tip and the cooled-tip procedures. Number of applications (9.9+/-11 versus 18.6+/-15 minutes; P<0.0001) and x-ray exposure (11.7+/-11 versus 19.5+/-16 minutes, P=0.0001) differed significantly between patients with short and long CTIs. Patients with short and straight CTIs required 3 times fewer RFA applications and shorter x-ray exposure compared with other CTI morphologies (pouch-like recesses and concave characteristics). CONCLUSIONS The number of RF applications required for a complete isthmus block in long CTIs is not influenced by the choice between an 8-mm or cooled-tip catheter. Procedure parameters, however, are significantly influenced by CTI length and morphology. Pouch-like recesses and concave characteristics account for much longer ablation times at all CTI lengths.
منابع مشابه
Successful irrigated-tip catheter ablation of atrial flutter resistant to conventional radiofrequency ablation.
BACKGROUND Catheter ablation of typical right atrial flutter is now widely performed. The best end point has been demonstrated to be bidirectional isthmus block. We investigated the use of irrigated-tip catheters in a small subset of patients who failed isthmus ablation with conventional radiofrequency (RF) ablation. METHODS AND RESULTS Of 170 patients referred for ablation of common atrial f...
متن کاملRadiofrequency catheter ablation of common-type atrial flutter guided by conventional versus electroanatomical mapping.
Radiofrequency catheter (RF) ablation aiming the complete conduction block of the cavotricuspid isthmus has become treatment of choice for common type atrial flutter. Different approaches to guide the ablation procedure are used. For the conventional approach multipolar catheters in the right atrium and in the coronary sinus are required to detect the induction of conduction block via the isthm...
متن کاملSingle-catheter validation of bidirectional block during atrial flutter ablation
Introduction Radiofrequency catheter ablation (RFCA) of typical atrial flutter (AFL) is an effective and widely performed method of treatment. Confirmation of conduction block in the cavotricuspid isthmus (CTI) is the best endpoint of the procedure. Electrophysiological measurements for validation of CTI block are usually performed using 2 or 3 catheters. However, in some situations this multi-...
متن کاملRemote magnetic catheter navigation for cavotricuspid isthmus ablation in patients with common-type atrial flutter.
BACKGROUND Conventional catheter ablation of cavotricuspid isthmus (CTI)-dependent atrial flutter is a widely applied standard therapy. Remote magnetic catheter navigation (RMN) may provide benefits for different ablation procedures, but its efficacy for CTI ablation has not been evaluated in a randomized, controlled trial. METHODS AND RESULTS Ninety patients undergoing de novo ablation of at...
متن کاملEfficacy comparison between cryoablation and radiofrequency ablation for patients with cavotricuspid valve isthmus dependent atrial flutter: a meta-analysis
We perform this meta-analysis to compare the efficacy and safety of cryoablation versus radiofrequency ablation for patients with cavotricuspid valve isthmus dependent atrial flutter. By searching EMBASE, MEDLINE, PubMed and Cochrane electronic databases from March 1986 to September 2014, 7 randomized clinical trials were included. Acute (risk ratio[RR]: 0.93; P = 0.14) and long-term (RR: 0.94;...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Circulation
دوره 110 9 شماره
صفحات -
تاریخ انتشار 2004