Dynamic Mechanical Compression of Chondrocytes for Tissue Engineering: A Critical Review
نویسندگان
چکیده
Articular cartilage functions to transmit and translate loads. In a classical structure-function relationship, the tissue resides in a dynamic mechanical environment that drives the formation of a highly organized tissue architecture suited to its biomechanical role. The dynamic mechanical environment includes multiaxial compressive and shear strains as well as hydrostatic and osmotic pressures. As the mechanical environment is known to modulate cell fate and influence tissue development toward a defined architecture in situ, dynamic mechanical loading has been hypothesized to induce the structure-function relationship during attempts at in vitro regeneration of articular cartilage. Researchers have designed increasingly sophisticated bioreactors with dynamic mechanical regimes, but the response of chondrocytes to dynamic compression and shear loading remains poorly characterized due to wide variation in study design, system variables, and outcome measurements. We assessed the literature pertaining to the use of dynamic compressive bioreactors for in vitro generation of cartilaginous tissue from primary and expanded chondrocytes. We used specific search terms to identify relevant publications from the PubMed database and manually sorted the data. It was very challenging to find consensus between studies because of species, age, cell source, and culture differences, coupled with the many loading regimes and the types of analyses used. Early studies that evaluated the response of primary bovine chondrocytes within hydrogels, and that employed dynamic single-axis compression with physiologic loading parameters, reported consistently favorable responses at the tissue level, with upregulation of biochemical synthesis and biomechanical properties. However, they rarely assessed the cellular response with gene expression or mechanotransduction pathway analyses. Later studies that employed increasingly sophisticated biomaterial-based systems, cells derived from different species, and complex loading regimes, did not necessarily corroborate prior positive results. These studies report positive results with respect to very specific conditions for cellular responses to dynamic load but fail to consistently achieve significant positive changes in relevant tissue engineering parameters, particularly collagen content and stiffness. There is a need for standardized methods and analyses of dynamic mechanical loading systems to guide the field of tissue engineering toward building cartilaginous implants that meet the goal of regenerating articular cartilage.
منابع مشابه
The influence of cell-matrix attachment and matrix development on the micromechanical environment of the chondrocyte in tissue-engineered cartilage.
Insufficiency of mechanical properties of tissue-engineered (TE) cartilage grafts is still a limiting factor for their clinical application. It has been shown that mechanostimulation of chondrocytes enhances synthesis of extracellular matrix (ECM) and thereby improves the mechanical properties of the grafts. However, the optimal mechanical loading required to stimulate chondrocytes for sufficie...
متن کاملHigh Quality of Infant Chondrocytes in Comparison with Adult Chondrocytes for Cartilage Tissue Engineering
BACKGROUND Tissue engineering is used for the treatment of many diseases, and the ideal cell source for cartilage tissue engineering is chondrocytes. The main limitation of chondrocyte is the low number of cells in cartilage tissue engineering. This study investigated a suitable cell source with high proliferation rate to obtain a large number of chondrocytes. METHODS Adult cartilage t...
متن کاملEffect of Cyclic Dynamic Compressive Loading on Chondrocytes and Adipose-Derived Stem Cells Co-Cultured in Highly Elastic Cryogel Scaffolds
In this study, we first used gelatin/chondroitin-6-sulfate/hyaluronan/chitosan highly elastic cryogels, which showed total recovery from large strains during repeated compression cycles, as 3D scaffolds to study the effects of cyclic dynamic compressive loading on chondrocyte gene expression and extracellular matrix (ECM) production. Dynamic culture of porcine chondrocytes was studied at 1 Hz, ...
متن کاملA Review Study: Effect of Growth Factors on Human Mesenchymal Stem Cells Differentiation into Cartilage Tissue
Hyaline cartilage is a vascular and neural tissue with scanty chondrocytes and limited regenerative ability. After some serious injuries of the cartilage, healing process will take place through the formation of fibrocartilage structures. Currently, tissue engineering and cell therapy are 2 interesting therapeutic fields dealing with regenerative medicine. In this regard, tissue&...
متن کاملBiomechanical Analysis of CNS Gray Matter in Tension and Compression
The purpose of this study is to survey cross section changes of the animal brain samples during the tension and compression tests and comparison of the experimental results for three animals: bovine, sheep, and rabbit. A linear elastic theory with considering the necking in tension and barreling in compression has been considered for brain tissue. Bridgman method for tension and cross section u...
متن کامل