Analysis of benzene, toluene, ethylbenzene, xylenes and n-aldehydes in melted snow water via solid-phase dynamic extraction combined with gas chromatography/mass spectrometry.
نویسندگان
چکیده
The present study describes a method based on headspace-solid-phase dynamic extraction (HS-SPDE) followed by GC/MS for the qualitative and quantitative analysis of benzene, toluene, ethylbenzene, o-, m- and p-xylene (BTEX), and n-aldehydes (C(6)-C(10)) in water. To enhance the extraction capability of the HS-SPDE a new cooling device was tested that controls the temperature of the SPDE needle during extraction. Extraction and desorption parameters such as the number of extraction cycles, extraction temperature, desorption volume and desorption flow rate have been optimized. Detection limits for BTEX ranged from 19 ng/L (benzene) to 30 ng/L (m/p-xylene), while those for n-aldehydes ranged from 21 ng/L (n-heptanal) to 63 ng/L (n-hexanal). At a concentration level of 2 microg/L, the relative standard deviations (RSDs) for BTEX ranged from 3.9% (benzene) to 15.3% (ethylbenzene), while RSDs for n-aldehydes were between 6.1% (n-octanal) and 16.5% (n-hexanal) (n=7). Best results were obtained when the analyzed water samples were heated to 50 degrees C. At a water temperature of 70 degrees C GC responses decreased for all analyzed compounds. At a defined water temperature, a significant improvement of the GC response was achieved by cooling of the SPDE fiber during water extraction in comparison to an extraction keeping the fiber at room temperature. Evaluating the extraction cycles, for BTEX, the sensitivity was almost similar using 20, 40 and 60 extraction cycles. In contrast, the highest GC responses for n-aldehydes were achieved by the use of 60 extraction cycles. Optimizing the desorption parameters, best results were achieved using the smallest technical available desorption volume of 500 microL and the highest technical desorption flow rate of 50 microL/s. The method was applied to the analysis of melted snow samples taken from the Jungfraujoch, Switzerland (3580 m asl), revealing the presence of BTEX and aldehydes in snow.
منابع مشابه
Comparison between dynamic headspace and headspace solid-phase microextraction for gas chromatography of BTEX in urine.
The aim of this study was to compare two extraction procedures: dynamic headspace-purge and trap (PT) and headspace solid-phase microextraction (HS-SPME) for gas chromatographic determination of benzene, toluene, ethylbenzene, and isomeric xylenes (BTEX) in urine with photoionization (PID) and mass spectrometric (MS) detection, respectively. Both methods showed linearity in the range of interes...
متن کاملChemical characterization of volatile organic compounds on animal farms
More than one hundred volatile organic substances were identified by gas chromatography and mass spectrometry (GC/MS) in the indoor and outdoor air, stable and farm road dust and farm soil samples from two pig and cattle farms in the South Moravian Region. Volatile fatty acids (acetic, propanoic, butanoic and pentanoic acids) and their esters dominated along with aldehydes (butanal, pentanal an...
متن کاملDevelopment and Validation of Analytical Methodology for the Determination of Volatile Organic Compounds for Production and Certification of Reference Material
An analytical method has been developed and validated for the determination of benzene, toluene, ethylbenzene and xylenes (BTEX) using gas chromatography ion trap mass spectrometry (GC IT MS ID) with isotope dilution. The limits of detection (LOD) and limits of quantification (LOQ) were always lower than 5 and 15 ug/g, respectively. The linear correlation coefficients were always greater than 0...
متن کاملDetermination of benzene, toluene, ethylbenzene and xylene in river water by solid-phase extraction and gas chromatography.
A rapid and reproducible method is described that employs solid-phase extraction (SPE) using dichloromethane, followed by gas chromatography (GC) with flame ionization detection for the determination of benzene, toluene, ethylbenzene, xylene and cumene (BTEXC) from Buriganga River water of Bangladesh. The method was applied to detect BTEXC in a sample collected from the surface, or 5 cm depth o...
متن کاملDetermining the Levels of Volatile Organic Pollutants in Urban Air Using a Gas Chromatography-Mass Spectrometry Method
The paper presents the application of a method based on coupled gas chromatography-mass spectrometry, using an isotopically labelled internal standard for the quantitative analysis of benzene (B), toluene (T), ethyl benzene (E), and o-, m-, p-xylenes (X). Their atmospheric concentrations were determined based on short-term sampling, in different sites of Cluj-Napoca, a highly populated urban ce...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of chromatography. A
دوره 1178 1-2 شماره
صفحات -
تاریخ انتشار 2008