Rates of positive cardiac troponin I and creatine kinase MB mass among patients hospitalized for suspected acute coronary syndromes.

نویسندگان

  • Joseph C Lin
  • Fred S Apple
  • MaryAnn M Murakami
  • Russell V Luepker
چکیده

BACKGROUND Cardiac troponin I (cTnI) is a more specific and sensitive biomarker than creatine kinase MB (CKMB) for detection of myocardial damage. We report the prevalence of positive cTnI and CKMB mass among patients hospitalized with suspected acute coronary syndrome (ACS) and the potential impact of use of different reference cutoffs, particularly those proposed by European Society of Cardiology/American College of Cardiology (ESC/ACC) consensus guidelines, on rates of diagnosis of acute myocardial infarction (AMI). METHODS We analyzed 1719 consecutive patients with suspected ACS admitted to an urban acute care hospital over a 6-month period. Patients (> or = 18 years of age) had at least two separate sets of plasma biomarkers (cTnI and CKMB) measured more than 12-24 h after admission to determine the potential rates of AMI based on different biomarker cutoff concentrations. RESULTS The prevalence of cTnI-positive cases ranged from 10.6%, based on a cutoff of twice the ROC curve (cTnI < or =1.2 microg/L), to 25.0%, using the ESC/ACC-recommended 99th percentile cutoff (cTnI <0.1 microg/L). The prevalence of CKMB-positive cases ranged from 10.4%, with the cutoff of twice the ROC curve (CKMB < or =10.0 microg/L) to 21.7%, with the 99th percentile cutoff (CKMB <3.9 microg/L). Use of the 10% CV cutoff (cTnI < or =0.3 microg/L and CKMB <3.9 microg/L) instead of the ROC cutoff produced a 26% increase in all cTnI-positive cases. Use of the 99th percentile reference cutoff instead of the ROC curve-derived cutoff produced an 85% increase in all cTnI-positive cases. A substantial proportion of the increase in total cTnI-positive cases was derived from cTnI-positive/CKMB-negative cases: 71 (4.1%), 73 (4.2%), 98 (5.7%), and 209 (12.2%) of cTnI-positive cases were CKMB-negative, as determined by the twice the ROC, ROC, 10% CV, and 99th percentile reference cutoffs, respectively. At the 99th percentile cutoffs, 8.8% of cases were CKMB-positive/cTnI-negative. CONCLUSIONS Use of lower reference cutoffs for plasma biomarkers, as recommended by ESC/ACC guidelines, markedly increases the rates of cTnI-positive cases overall. A substantial proportion of the increase in total cTnI-positive cases was derived from the creation of additional cTnI-positive/CKMB-negative cases. CKMB-positive/cTnI-negative cases are likely false positive for myocardial injury.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of pregnancy-associated plasma protein-A, troponin and creatine kinase-MB levels in acute coronary syndrome

Background: Early diagnosis and proper treatment of patient with acute coronary syndrome (ACS) and ischemic heart disease are important in determining prognosis, preventing adverse effects, and may even save lives. In this study, the level of pregnancy-associated plasma protein-A (PAPP-A) in ACS patients was compared with the control group, in addition to cardiac Troponin (cTn) and creatine kin...

متن کامل

CARDIOVASCULAR MEDICINE Multicentre evaluation of the diagnostic value of cardiac troponin T, CK-MB mass, and myoglobin for assessing patients with suspected acute coronary syndromes in routine clinical practice

Objective: To assess the diagnostic efficiency of the third generation cardiac troponin T assay in routine clinical practice. Design: Prospective observational study of unselected consecutive admissions. Setting: Multicentre study in 43 teaching and non-teaching hospitals in 13 countries. Subjects: 1105 hospital admissions, median age 67 years (range 15–96 years, 63.7% male) with suspected acut...

متن کامل

Multicentre evaluation of the diagnostic value of cardiac troponin T, CK-MB mass, and myoglobin for assessing patients with suspected acute coronary syndromes in routine clinical practice.

OBJECTIVE To assess the diagnostic efficiency of the third generation cardiac troponin T assay in routine clinical practice. DESIGN Prospective observational study of unselected consecutive admissions. SETTING Multicentre study in 43 teaching and non-teaching hospitals in 13 countries. SUBJECTS 1105 hospital admissions, median age 67 years (range 15-96 years, 63.7% male) with suspected ac...

متن کامل

Cardiac enzyme in emergency medicine

Objective: Acute chest pain is an important and frequently occurring symptom in patients. Chest pain is often a sign of ischemic heart disease. Chest pain due to suspected Acute Coronary Syndrome (ACS) is responsible for a large and ijncreasing number of hospital attendances and admissions. Current practice for suspected ACS involves troponin testing 10–12 hours after symptom o...

متن کامل

Analytical performance and clinical application of a new rapid bedside assay for the detection of serum cardiac troponin I.

Detection of cardiac troponin I (cTnI) in patients suspected of having an acute coronary syndrome is highly predictive for an adverse outcome. We evaluated a bedside test for cTnI that uses a polyclonal capture antibody and two monoclonal indicator antibodies. Clinical studies were performed in patients with acute coronary syndrome and patients with chest pain but no evidence of acute myocardia...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical chemistry

دوره 50 2  شماره 

صفحات  -

تاریخ انتشار 2004