Left ventricular mass: reliability of M-mode and 2-dimensional echocardiographic formulas.

نویسندگان

  • Saul G Myerson
  • Hugh E Montgomery
  • Michael J World
  • Dudley J Pennell
چکیده

The study of left ventricular (LV) hypertrophy is hindered by problems with LV mass measurement by echocardiography. Both the M-mode and 2D area-length formulas for calculating LV mass assume a fixed geometric shape, which may be a source of error. We examined this hypothesis by using cardiovascular magnetic resonance images to eliminate the confounding effects of acoustic access and image quality. LV mass was measured directly in 212 healthy subjects by means of a standard 3D cardiovascular magnetic resonance technique. LV mass was also calculated by using the cube-function and area-length formulas with measurements from the magnetic resonance images. A comparison of serial measurements was made by examining the changes in LV mass by all 3 techniques in those completing an exercise program (n=140). The cube-function technique showed a consistent underestimation of LV mass of 14.3 g, and there were wide 95% limits of agreement (+/-57.6 g and +/-46.3 g for cube-function and area-length techniques, respectively) when compared with 3D measurement. There were similarly wide limits of agreement for the change in mass (+/-55.2 g and +/-44.8 g for cube-function and area-length, respectively). The assumption of geometric shape in the cube-function and area-length formulas resulted in significant variation in LV mass estimates from direct measurement by using a 3D technique. The technique cannot be recommended either at a single time point or for serial studies in small populations; 3D imaging techniques, such as cardiovascular magnetic resonance, are preferable.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Reference values of M-mode echocardiographic parameters and indices in conscious Labrador Retriever dogs

Breed-wise standard echocardiographic values in dogs have been reported as there is variation in body and chest conformation which limits the application of data of one breed for other breed. Labrador Retrievers being originated from hunting dogs, might have different echocardiographic values from standard normal range of other dog breeds. So, the present study was aimed to determine the M-mode...

متن کامل

Comparison of echocardiography with magnetic resonance imaging in the assessment of the athlete's heart.

AIM The purpose of the study was to compare the accuracy of M-mode echocardiography and two different two-dimensional echocardiographic approaches in the assessment of left ventricular mass and volumes in endurance-trained and strength-trained athletes, using magnetic resonance imaging as reference standard. METHODS AND RESULTS We studied 19 athletes and 10 untrained control subjects, M-mode ...

متن کامل

Detection of left ventricular hypertrophy by M-mode echocardiography. Anatomic validation, standardization, and comparison to other methods.

Because of its simplicity, widespread availability, relatively low cost, and lack of adverse effects, M-mode echocardiography has become the most widely used technique for measurement of human left ventricular mass. Necropsy comparison studies have yielded formulas for anatomically accurate estimation of left ventricular mass in patients with normally shaped ventricles using left ventricular me...

متن کامل

Echocardiographic assessment of myocardial infarction: comparison of a rat model in two strains

The purpose of this study was to induce myocardial infarction (MI) and compare the echocardiographic parameters and mortality ratio of Lewis inbred and Wistar outbred strain before and after the procedure to help choose the best one for MI studies. In this study MI was induced in 46 Lewis and 34 Wistar by occlusion of left anterior descending artery (LAD). Doppler, two-dimensional (2-D) and 2-D...

متن کامل

Accuracy of echocardiography versus electrocardiography in detecting left ventricular hypertrophy: comparison with postmortem mass measurements.

The accuracy of electrocardiography, M-mode echocardiography and two-dimensional echocardiography in predicting left ventricular hypertrophy was compared in 50 patients who came to autopsy within 6 months after the studies were performed. Several methods for determining left ventricular hypertrophy were examined for each of the three techniques. M-mode echocardiography was technically adequate ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Hypertension

دوره 40 5  شماره 

صفحات  -

تاریخ انتشار 2002