Enhanced lateral flow immunoassay using gold nanoparticles loaded with enzymes.

نویسندگان

  • Claudio Parolo
  • Alfredo de la Escosura-Muñiz
  • Arben Merkoçi
چکیده

The use of gold nanoparticles (AuNPs) as labeling carriers in combination with the enzymatic activity of the horseradish peroxidase (HRP) in order to achieve an improved optical lateral flow immunoassay (LFIA) performance is presented here. Briefly in a LFIA with an immune-sandwich format AuNPs are functionalized with a detection antibody already modified with HRP, obtaining an 'enhanced' label. Two different detection strategies have been tested: the first one following just the red color of the AuNPs and the second one using a substrate for the HRP (3 different substrates are evaluated), which produces a darker color that enhances the intensity of the previous red color of the unmodified AuNPs. In such very simple way it is gaining sensitivity (up to 1 order of magnitude) without losing the simplicity of the LFIA format, opening the way to other LFIA applications including their on-demand performance tuning according to the analytical scenario.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Lateral flow immunoassay with the signal enhanced by gold nanoparticle aggregates based on polyamidoamine dendrimer.

In order to amplify the signal in a gold nanoparticle-based lateral flow immunoassay, a simple and sensitive method utilizing gold nanoparticle aggregates as a colored reagent formed with a polyamidoamine dendrimer was developed. The results were compared with that achieved by employing the individual nanoparticles used in the conventional lateral flow immunoassay. Under the optimized experimen...

متن کامل

Lateral flow immunoassay using europium chelate-loaded silica nanoparticles as labels.

BACKGROUND Despite their ease of use, lateral flow immunoassays (LFIAs) often suffer from poor quantitative discrimination and low analytical sensitivity. We explored the use of a novel class of europium chelate-loaded silica nanoparticles as labels to overcome these limitations. METHODS Antibodies were covalently conjugated onto europium chelate-loaded silica nanoparticles with dextran as a ...

متن کامل

Development of a Lateral Flow Immunoassay Using Recombinant Dense Granular Antigen (GRA) 7 to Detect Anti-Toxoplasma gondii IgG Antibodies

Toxoplasma gondii is an intracellular protozoan parasite that causes toxoplasmosis and is of medical importance in pregnant women and immunosuppressed patients. In recent years, many methods have been developed for the detection of infection caused by this parasite; however, most of the developed methods are not adequately sensitive. The dense granular antigen (GRA) ...

متن کامل

Simple paper architecture modifications lead to enhanced sensitivity in nanoparticle based lateral flow immunoassays.

Lateral flow immunoassays (LFIA) are ideal biosensors to detect proteins, but their lack of sensitivity hinders their extensive use. We report a strategy that yields up to an 8-fold improvement in the sensitivity of a gold nanoparticles-based LFIA by changing the sizes of the pads. Theoretical flow simulations of the developed LFIA architectures are in accordance with the experimental results.

متن کامل

Increased sensitivity of lateral flow immunoassay for ochratoxin A through silver enhancement.

Silver nucleation on gold has been exploited for signal amplification and has found application in several qualitative and quantitative bio-sensing techniques, thanks to the simplicity of the method and the high sensitivity achieved. Very recently, this technique has been tentatively applied to improve the performance of gold-based immunoassays. In this work, the exploitation of the signal ampl...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Biosensors & bioelectronics

دوره 40 1  شماره 

صفحات  -

تاریخ انتشار 2013