Modeling Validation and Control Analysis for Controlled Temperature and Humidity of Air Conditioning System
نویسندگان
چکیده
This study constructs an energy based model of thermal system for controlled temperature and humidity air conditioning system, and introduces the influence of the mass flow rate, heater and humidifier for proposed control criteria to achieve the controlled temperature and humidity of air conditioning system. Then, the reliability of proposed thermal system model is established by both MATLAB dynamic simulation and the literature validation. Finally, the PID control strategy is applied for controlling the air mass flow rate, humidifying capacity, and heating, capacity. The simulation results show that the temperature and humidity are stable at 541 sec, the disturbance of temperature is only 0.14 °C, 0006 kg(w)/kg(da) in steady-state error of humidity ratio, and the error rate is only 7.5%. The results prove that the proposed system is an effective controlled temperature and humidity of an air conditioning system.
منابع مشابه
Designing Fuzzy Controller for Air Conditioning Systems in order to Save Energy Consumption and Provide Optimal Conditions in Closed Environments (Indoors)
Today air conditioning systems have been considered by all people as one of welfarerequirements in buildings and closed environments. Since a considerable part of energy lossoccurs in ordinary modern systems, new strategies and solutions are developed in the field inorder to save amount of energy consumption and observe environmental considerations. Fuzzycontrol is one of these methods which pr...
متن کاملThermal modeling of mini-channel and laminated Types evaporator in mobile air conditioning system
In this paper, mini-channel type evaporator which is new in mobile air conditioning (MAC) or automotive air conditioning (AAC) systems is thermally modeled. The performance of mini-channel evaporator is also compared with the laminated evaporator which is being currently used in automotive industries. The mini-channel evaporator was constructed of two rows of parallel flow mini-channel tubes...
متن کاملPattern Changes Analysis Of Soil Temperature In Different Depths Under The Influence Of Humidity And Air Temperature (Case Study: Taleghan Watershed)
In this study, to analyze the pattern of soil temperature changes in the depths of 5, 10, 20, 30, 50 and 100 cm under the influence of temperature (minimum, average and maximum) and humidity (minimum, average and maximum) the Pearson and regression methods were used for Taleghaan synoptic station during the period of 2008 to 2016 . The results showed that soil temperature had the highest corre...
متن کاملDesign and operation optimization of an air conditioning system through simulation: an hour-by-hour simulation study
In the present research, performance validation of a Heating, Ventilation, and Air Conditioning (HVAC) system operating in a library building was conducted. The operating HVAC system was studied in terms of the provided indoor air conditions and energy consumption level. The fieldwork measurements showed that the HVAC system is not capable of providing the desired indoor air conditions based on...
متن کاملDesign and Implementation of Air Conditioning System in Operating Room
The system is air conditioning system in operating room. The main objective of the system was implemented to provide air balance and temperature necessary conditions and to control airflow system for ventilation units in operating room. The operation room can be controlled with fuzzy expert system and describes the desired outputs. Input parameters such as temperature, humidity, oxygen and part...