Non-invasive assessment of liver fibrosis with transient elastography (FibroScan®): applying the cut-offs of M probe to XL probe.

نویسندگان

  • Grace Lai-Hung Wong
  • Julien Vergniol
  • Peter Lo
  • Vincent Wai-Sun Wong
  • Juliette Foucher
  • Brigitte Le Bail
  • Paul Cheung-Lung Choi
  • Faiza Chermak
  • Kwong-Sak Leung
  • Wassil Merrouche
  • Henry Lik-Yuen Chan
  • Victor de Lédinghen
چکیده

UNLABELLED BACKGROUND AND RATIONALE FOR THE STUDY: Limited studies have aimed to define the cut-offs of XL probe (XL cut-offs) for different stages of liver fibrosis, whereas those of M probe (M cut-offs) may not be applicable to XL probe. We aimed to derive appropriate XL cut-offs in overweight patients. Patients with liver stiffness measurement (LSM) by both probes were recruited. XL cut-offs probe for corresponding M cut-offs were derived from an exploratory cohort, and subsequently validated in a subgroup patients also underwent liver biopsy. The diagnostic accuracy of XL cut-offs to diagnose advanced fibrosis was evaluated. RESULTS Total 517 patients (63% male, mean age 58) who had reliable LSM by both probes were included in the exploratory cohort. There was a strong correlation between the LSM by M probe (LSM-M) and LSM by XL probe (LSM-XL) (r² = 0.89, p < 0.001). A decision tree using LSM-XL was learnt to predict the 3 categories of LSM-M (< 6.0kPa, 6.0-11.9kPa and ≥ 12.0kPa), and XL cut-offs at 4.8kPa and 10.7kPa were identified. These cut-offs were subsequently validated in a cohort of 147 patients who underwent liver biopsy. The overall accuracy was 89% among 62 patients whose LSM-XL < 4.8kPa or ≥ 10.7kPa. These cut-offs would have avoided under-staging of fibrosis among patients with body mass index (BMI) > 25-30 kg/m2 but not > 30 kg/m2. CONCLUSIONS XL cut-offs at 4.8kPa and 10.7kPa were the best estimates of 6.0kPa and 12.0kPa of M probe for patients with BMI > 25-30 kg/m2. Patients with BMI > 30 kg/m² might use M probe cut-offs for XL probe.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Update of liver fibrosis and steatosis with transient elastography (Fibroscan)

BACKGROUND Assessment of liver fibrosis and steatosis is now almost indispensable in most of the chronic liver diseases in order to determine prognosis and need for treatment, and to monitor disease progression and response to treatment. Liver biopsy is limited by its invasiveness and patient acceptability. Transient elastography (TE; Fibroscan) is a non-invasive tool with satisfactory accuracy...

متن کامل

Assessment of transient elastography (FibroScan) for diagnosis of fibrosis in non-alcoholic fatty liver disease: A systematic review and meta-analysis

Background: Transient elastography (TE) is a new modality for the diagnosis of liver fibrosis caused by various etiologies. This study was conducted to determine the accuracy of TE in detecting the different stages of liver fibrosis in non-alcoholic fatty liver disease (NAFLD) patients. Methods: MEDLINE/PubMed, Embase, Ovid, Cochrane Library, American College of Physicians (ACP) Journal Club...

متن کامل

Feasibility and reliability of the FibroScan S2 (pediatric) probe compared with the M probe for liver stiffness measurement in small adults with chronic liver disease.

BACKGROUND The success of liver stiffness measurement (LSM) by transient elastography (TE, FibroScan) is influenced by anthropometric factors. In smaller adults, the M probe may fail due to narrow intercostals spaces and rib interference. We aimed to compare LSM using the FibroScan S2 (pediatric) probe with the M probe in small adults with chronic liver disease. MATERIAL AND METHODS In this p...

متن کامل

Comparison between the M and XL probes for liver fibrosis assessment by transient elastography.

OBJECTIVE Liver stiffness measurement (LSM) using Transient Elastography (TE) for liver fibrosis assessment is difficult to be performed in obese and overweight patients by standard M probe, thus the XL probe was developed. The aim of our paper was to assess the usefulness of the XL probe in daily clinical practice. MATERIAL AND METHOD Our study included 216 patients (mean BMI 30.1+/-4.1 kg/m...

متن کامل

Transient Elastography (FibroScan) Performs Better Than Non-Invasive Markers in Assessing Liver Fibrosis and Cirrhosis in Autoimmune Hepatitis Patients

BACKGROUND Autoimmune hepatitis (AIH) is an immune-mediated chronic liver disease that can lead to severe fibrosis and cirrhosis. Transient elastography (TE, FibroScan) can assess the fibrotic stages of chronic liver diseases by liver stiffness measurement (LSM). Studies on the diagnostic accuracy of FibroScan for the detection of fibrosis in AIH patients are still limited. MATERIAL AND METHODS...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Annals of hepatology

دوره 12 4  شماره 

صفحات  -