Unreliability of automatic scoring of MESAM 4 in assessing patients with complicated obstructive sleep apnea syndrome.

نویسندگان

  • F Cirignotta
  • S Mondini
  • R Gerardi
  • B Mostacci
  • E Sancisi
چکیده

BACKGROUND Portable devices are used for unattended recording of patients with suspected obstructive sleep apnea syndrome (OSAS). The MESAM 4 (MAP; Martinsried, Germany) is a computerized ambulatory polysomnographic system that records four parameters: breathing noise, heart rate, arterial oxygen saturation (SaO(2)), and body position. DESIGN AND METHOD We evaluated the reliability of the oxygen desaturation index (ODI) automatically calculated by the MESAM 4 device in evaluating patients with "complicated" OSAS. These patients present SaO(2) drops due to apneas associated with a fall in baseline SaO(2) during sleep, as occurs in the "overlap syndrome." Ten patients with complicated OSAS underwent nocturnal MESAM 4 recordings, and we compared the visual and automatic scorings of the ODI. RESULTS The ODI obtained with visual scoring was significantly higher than ODI automatically calculated by the MESAM 4 in all patients. In some patients, this difference was so significant that it could bias clinical judgment of OSAS severity. We demonstrated that the system did not identify those desaturation events that were superimposed on a fall in baseline SaO(2). The error depends on the algorithm by which the device recognizes the desaturation events and calculates the baseline SaO(2). CONCLUSION Automatic analysis of MESAM 4 recordings may be misleading in evaluating OSAS patients who have a fall in baseline SaO(2) during sleep. In this case, visual scoring performed by a trained polysomnographer is recommended.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Hand-scoring of MESAM 4 recordings is more accurate than automatic analysis in screening for obstructive sleep apnoea.

The MESAM 4 system, developed to monitor breathing sounds, heart rate, arterial oxygen saturation (Sao2) and body position, was proposed as a screening method for obstructive sleep apnoea (OSA). The aim of the study was to assess the accuracy of hand-scoring versus automatic-scoring in screening for obstructive sleep apnoea. The study population consisted of 56 patients, 51 males, and 5 females...

متن کامل

Investigations of an automatic screening device (MESAM) for obstructive sleep apnoea.

A digital recording device developed to monitor heart rate (HR) and breathing sounds (snoring), and used to screen subjects for obstructive sleep apnoea syndrome (OSAS), was investigated. This device is called the MESAM and is currently commercially available in some western European countries. The computer-based automatic scoring systems provided with the equipment and a hand-scoring technique...

متن کامل

Diagnostic accuracy of a portable recording device (MESAM IV) in suspected obstructive sleep apnoea.

This study evaluated the accuracy of a portable recording device (MESAM IV) in identifying obstructive sleep apnoea (OSA). The MESAM IV system measures arterial oxygen saturation (Sa,O2), heart rate, snoring sounds and body position, and allows both automatic and manual scoring of the recordings. Nocturnal polysomnography and MESAM IV recordings were performed simultaneously in 150 patients wit...

متن کامل

Determination of The Relationship Between Severity of Obstructive Sleep Apnea And Chronic Obstructive Pulmonary Disease

Introduction: Chronic obstructive pulmonary disease (COPD) patients are at increased risk of sleep-disorders. The concomitant occurrence of COPD and obstructive sleep apnea hypopnea syndrome (OSAHS) is named overlap syndrome. This study aimed to evaluate the severity of OSAHS in overlap syndrome patients.Materials & Methods: This cross-sectional study was conducted on adult patients with forced...

متن کامل

Apert Syndrome with Obstructive Sleep Apnea: A Case Report

Apert syndrome is a rare kind of craniosynostosis which is identified with fusion of cranial sutures during prematurity period and causes physical and intellectual disorders in younger ages. These patients may show symptoms of obstructive sleep apnea due to abnormal craniofacial shape. This article introduces a patient with Apert syndrome, with apnea symptoms, cyanosis, snoring, restlessness, n...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Chest

دوره 119 5  شماره 

صفحات  -

تاریخ انتشار 2001